background image

TECHNICAL GUIDE

AFFINITY 

MODELS: PV9

GAS-FIRED
CONDENSING / HIGH EFFICIENCY 
TWO STAGE VARIABLE 
UPFLOW FURNACES

UP TO 94% AFUE

NATURAL GAS
40 - 120 MBH INPUT

Due to continuous product improvement, specifications 
are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

Additional rating information can be found at 
www.gamanet.org.

EFFICIENCY
RATING
CERTIFIED

This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.

036-21584-001 Rev. B (1004)

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room
or garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented
using approved plastic type combustion air and vent piping.
All units are factory assembled, wired and tested to assure
dependable and economical installation and operation.

WARRANTY

Lifetime limited warranty on  both heat exchangers to the
original purchaser; a 20-year limited warranty from original
installation date to subsequent purchaser.

10-year warranty on commercial applications.

5-year limited parts warranty.

FEATURES

Two stage heating operation includes:

- Two stage gas valve
- Two stage inducer operation
- Variable speed ECM blower operation

Provides increased comfort level & very quiet unit oper-
ation

Adjustable delay timer allows two stage operation with 
single stage thermostat

• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-

tion.

• Integrated control module for reliable, economical opera-

tion.

• High velocity filter and side -return filter rack provided for 

easy field installation.

• May be installed as either two-pipe (sealed combustion) 

or single pipe vent (using indoor combustion air)

• Top intake & vent connection allows installation in narrow 

locations.

• Electronic Hot Surface Ignition saves fuel cost with 

increased dependability and reliability.

• Induced combustion system with inshot main burners for 

quiet, efficient operation.

• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• 24V, 40 VA control transformer and blower relay supplied 

for add-on cooling.

• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary (condensing) heat exchanger of 29-4C high-

grade stainless steel.

• Timed on, adjustable off blower capability for maximum 

comfort.

• Solid removable bottom panel allows easy application.
• Easy access from front of unit for cleaning, maintenance 

or service.

• Protection from intake, exhaust or condensate blockage.
• Insulated blower compartment for quiet operation.
• ClimaTraK comfort system allows dealer to customize 

comfort settings based on regional location.

Summary of Contents for PV9

Page 1: ...age inducer operation Variable speed ECM blower operation Provides increased comfort level very quiet unit oper ation Adjustable delay timer allows two stage operation with single stage thermostat Compact easy to install ideal height 40 cabinet Blower off delay for cooling SEER improvement Easy to connect power control wiring Built in high level self diagnostics with fault code display Low unit am...

Page 2: ...nsion Air Intake A in B in C in D in PV9A12N040UP11 1200 A 14 1 2 13 1 2 12 1 8 6 1 4 PV9B12N060UP11 1200 B 17 1 2 16 1 4 15 1 8 8 1 2 PV9B12N080UP11 1200 B 17 1 2 16 1 4 15 1 8 8 1 2 PV9C16N080UP11 1600 C 21 19 3 4 18 1 2 8 7 8 PV9C20N100UP11 2000 C 21 19 3 4 18 1 2 8 7 8 PV9D20N120UP11 2000 D 24 1 2 23 1 4 21 7 8 10 5 8 COMBUSTION AIR SUPPLY AND VENT PIPING MAXIMUM ELBOWS AND VENT LENGTHS Models...

Page 3: ...V9B12N080UP11 1PS0502 PV9C16N080UP11 1PS0503 PV9C20N100UP11 1PS0505 PV9D20N120UP11 1PS0503 ELECTRICAL AND PERFORMANCE DATA Models Input High Low Output High Low Nominal Airflow AFUE Air Temp Rise Max Outlet Air Temp Blower Blower Size Total Unit Max Over current Protect Min Wire Size awg 75 ft One Way MBH MBH CFM F F HP Amps In Amps PV9A12N040UP11 40 26 38 24 1200 94 0 35 65 165 1 2 7 7 11x8 9 20 ...

Page 4: ...1880 1250 53 2 35 4 A C 1560 1010 44 2 28 6 1620 1030 45 9 29 2 C B 1470 940 41 6 26 6 1500 960 42 5 27 2 B C 1370 890 38 8 25 2 1410 880 39 9 24 9 D B 1460 930 41 3 26 3 1490 920 42 2 26 1 C A 1250 790 35 4 22 4 1290 790 36 5 22 4 D A 1310 810 37 1 22 9 1360 840 38 5 23 8 C C 1090 690 30 9 19 5 1140 690 32 3 19 5 D C HIGH LOW HEAT CFM 40 000 INPUT 3 Ton 60 000 INPUT 3 Ton JUMPER SETTINGS CFM m mi...

Page 5: ...em static 5 If total system static matches a ESP value in the airflow table i e 0 20 0 60 etc the system airflow corre sponds to the intersection of the ESP column and Model Blower Speed row BLK WHT GRN BLK HOT WHT NEUTRAL GRN NOMINAL 120 VOLT LINE WIRING CONNECTIONS SINGLE STAGE HEATING THERMOSTAT CONNECTIONS SINGLE STAGE HEATING AND TWO STAGE COOLING THERMOSTAT CONNECTIONS ROOM THERMOSTAT FURNAC...

Page 6: ...to the bottom of the furnace 1BR0314 For 14 1 2 cabinets 1BR0317 For 17 1 2 cabinets 1BR0321 For 21 cabinets 1BR0324 For 24 1 2 cabinets HIGH ALTITUDE PRESSURE SWITCHES These accessory kits may be used to convert units for high altitude operation Conversion must be made by qualified dis tributor or dealer personnel 1PS0501 HIGH ALTITUDE PRESSURE SWITCH KIT Does Not Include Orifices FOR APPLICATION...

Page 7: ...036 21584 001 Rev B 1004 Unitary Products Group 7 NOTES ...