28
Regency Plateau™ Series Outdoor Gas Fireplace
28
OPERATING INSTRUCTIONS
FIRST FIRE
The fi rst fi re in your decorative gas appliance is part
of the paint curing process. To ensure that the paint
is properly cured, it is recommended that you burn
your decorative gas appliance for at least one (1)
hour the fi rst time you use it.
When fi rst operated, the unit will release an odour
caused by the curing of the paint, the burning off of
any oils remaining from manufacturing.
The glass surround may require cleaning after the
unit has cooled down.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS HOT.
INDOOR STORAGE OF
CYLINDERS
1)
There is no limitation on the storage of appliance
indoors provided that the cylinder is removed
from the appliance.
2)
Storage of an appliance indoors with the cyl-
inder attached is only permitted if the size
of the cylinder complies with AS/NZS 1596:
otherwise cylinder must be stored outdoors in
a well ventilated area.
WARNINGS/
IDENTIFICATION FOR
LEAKS
1)
Certain combustible materials under or near
the appliance will be subject to radiant heat
and could be seriously damaged.
2)
Inspect all hose assemblies before each use.
3) Check all hose assemblies for wear. Replace
if required.
4) Check all connections with soap and water,
clean after as some detergents are corrosive.
5)
Check all connection, fi tting, hoses prior to
each use.
OPERATING
INSTRUCTIONS
1)
Read and understand these instructions before
operating this appliance.
2)
Check to see that all wiring is correct and
enclosed to prevent possible shock.
3)
Check to ensure there are no gas leaks.
4)
Check all hoses and connections.
5)
The unit should never be turned off, and on
again without a minimum of a 60 second wait.
LIGHTING PROCEDURE
1)
Turn on ON/OFF switch.
2)
After approximately 4 seconds the spark igni-
tion system will spark for 60 seconds to light
the main burner.
3)
The unit will turn on.
Note:
The fi rst try for ignition will last approximately
60 seconds. If there is no fl ame ignition (rectifi -
cation) the board will stop sparking for approxi-
mately 35 seconds. After wait time , the board
will start second try for ignition by sparking for
approximately 60 seconds . If there is still no
positive ignition the board will go into lock out.
The system will need to be reset as follows:
a)
Turn the system off using ON/OFF switch.
b)
After approximately 2 seconds turn on ON/
OFF switch.
c)
Unit will repeat step 2.
SHUTDOWN
PROCEDURE
1)
Turn ON/OFF switch.
2)
If service is to be performed - you must discon-
nect the battery pack.