Regency PG33 Gas Inbuilt
17
INSTALLATION
53.6” (1362mm)
Minimum
Height
Requirement
8"(0.2m)
2’ (0.6m)
0
Horizontal (M)
0.6
1.2
1.8
2.4
3
3.6
4.2
4.8
5.4
6
V
ertical Height (M)
3
3.6
4.2
4.8
0
0.6
1.2
1.8
2.4
FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS
SIMPSON DURA-FLUE DIRECT FLUE GS SYSTEM and
REGENCY DIRECT FLUE SYSTEM (FLEX)
(ULPG with NG/LPG Burner)
This diagram shows all allowable combinations of vertical runs with horizontal terminations,
using one 45
o
and one 90
o
elbow
(two 45
o
elbows equal
one 90
o
elbow).
Note: Must use optional flue adapter (Part # 510-994) when using Simpson Dura-Vent pipe. (Refer to page 13.)
• Maintain clearances to combustibles.
• Horizontal flue must be supported every 3 feet.
• Firestops are required at each floor level and whenever passing through a wall.
A flue guard should be used whenever the termination is
lower than the specified minimum or as per local codes.
Note: Regency Direct Flue System (Flex) is only ap-
proved for horizontal terminations.
IMPORTANT NOTE
If the Burner is not a ULPG Burner, a
minimum flue rise of 1362mm (total height
from the floor)
MUST BE adhered to.