Regency PG33 Gas Inbuilt
35
MAINTENANCE
FAN REPLACEMENT
1)
Shut off the power supply.
2)
Remove the top louvre.
3)
Remove the glass door.
4)
Remove the 3 screws which secure the manual control box to the
bottom louvre and remove the bottom louvre.
5)
Unplug the 6 pin Molex connector and carefully pull out the ECS
box.
6)
Remove the electric cover by undoing the 2 screws, pull out the
grommet and the harness.
7)
Unplug the black wire from the resister.
8)
Carefully slide the fan to the front left side of the unit.
9)
Remove the screw which holds the ground wire and disconnect all
electrical connectors that are attached to the fan.
ECS Box
6 Pin Molex
Connector
10)
Pull out the fan.
Electric Cover
Ground Wire
Manual Con-
trol Box
11)
Reverse steps to install new fan.