INSTALLATION
6-7/8"
(173mm)
dia. Flue pipe
4" (102mm)
dia. flue pipe
Wall Thimble (2 pc)
(required in
Canada only)
Termination Cap
(Part# 946-523/P)
AstroCap
TM
spring
spacer
REGENCY DIRECT FLUE SYSTEM (FLEX)
HORIZONTAL TERMINATIONS ONLY
This flueing system, in combination with the PG33 Direct Flue Gas Fireplace, have been tested and listed as a direct flue heater system by AGA. The
location of the termination cap must conform to the requirements in the Flue Terminal Locations diagram on page 10.
Regency Direct Flue (Flex) System Termination Kit (Part # 946-513) includes all the parts needed to install the PG33 with a maximum
run of 2 feet.
If installing the P33 with a
continuous
flue length of more than 2 ft (.6m) to a maximum of 10 ft. (3.0m) using Kit # 946-515 (4 ft) or
946-516 (10 ft) or see page 13 for alternate flueing arrangements.
1)
6-7/8" dia. flexible liner (2 ft. length)
2)
4" dia. flexible liner (2 ft. length)
3)
spring spacers (3)
4)
thimble (2)
5)
AstroCap
termination cap (1)
6)
screws (12)
7)
tube of Mill Pac (1)
8)
plated screws (8)
9)
screws #8 x 1-1/2" drill point, stainless steel (4)
Wherever necessary due to external
location of cap, the AstroCap can
be replaced with the FPI Riser Flue
Termination Cap or the Dura-Vent
Snorkel Termination Cap.
See also
Figure 1 below.
Notes:
1) Liner sections should be continuous without any
joints or seams.
2) Only Flex pipe purchased from Regency may be
used for Flex installations.
Minimum Flex Kit Center-Line (NG
& LPG)
V
ertical Height (M)
Min. 26
”
(660mm)
Horizontal (M)
Max. 24"(0.6m)
0.6
0
1.8
1.2
2.4
0
0.6
1.2
1.8
2.4
IMPORTANT
If using any Cabinet Mantels with Part # 510956,
510958, 510962, 510964 and 510834 the wall thimble
must be secured first and flueing must be attached
to unit before sliding into final position.
Also Simpson Dura-Flue flueing cannot be used with
any of the mantels noted above.
Minimum Flex Kit Center-Line
(ULPG)
0
0.6
0
1.8
1.2
2.4
V
ertical Height (M)
Min. 49.6
”
(1260mm)
Horizontal (M)
Max. 24"(0.6m)
0.6
1.2
1.8
2.4
IMPORTANT NOTE
If the Burner is not a ULPG Burner,
a minimum flue rise of 1260mm
(total height from the floor)
MUST
BE adhered to.