Regency PG33NG4-R Gas Inbuilt
25
installation
PG33-4 / P33-3
2
918-576
12/06/06
19)
Stick the conversion label "This unit has
been converted to LPG" on the control
box cover.
Control Box
Cover
Antenna
17)
Remove the control box cover by
undoing the 3 screws. Maneuver through
antenna.
18)
Remove the jumper using a plier.
20)
Reverse steps 17 to 15.
21)
Check manual for venting confi gurations.
22)
Turn on gas supply and plug in power
cord.
23)
Adjusting the Outlet Pressure:
All the
adjustments must be carried out in the
following order:
Remove the modulator plastic cap (A)
using needle nose pliers.
Maximum pressure:
Turn the unit ON
to its highest input rating. Screw in the
nut (B) to increase the outlet pressure
and screw it out to decrease it. Use a 10
mm wrench.
Note:
The outlet pressure must be set to
maximum 2.61 kPa.
Minimum pressure:
Remove one of
the cables connected to the electric
modulator. Keeping the nut (B) blocked,
screw in the screw (C) to increase the
pressure and screw it out to decrease it.
Use a screwdriver 6 x 1 blade.
Note:
The outlet pressure must be set to
minimum 0.70 kPa.
After carrying out all adjustments, block
the setting screws with paint, taking care
not to obstruct the breather orifi ce of the
pressure.
Put back the modulator plastic cap.
24)
At the end of all setting and adjustment
operations, check electrical insulation
and gas leaks.
25)
Check operation of fl ame control.
26)
Check for proper fl ame appearance and
glow on logs.
Cable
Electric
Modulator
C
B
A
WARNING:
To ensure the correct operation
of the modulator it is necessary that the
plastic cap (A) is returned to its original
location.
Jumper
Jumper Location
Installer Notice:
These instructions must
be left with the appliance.
Summary of Contents for Panorama PG33LPG4-R