16
Regency PG33NG4-R Gas Inbuilt
installation
0
30” (762mm)
Minimum
Height
Requirement
Horizontal (M)
8"(0.2m)
2 (0.6m)
Vertical Height (M)
3
3.6
4.2
4.8
0
0.6
1.2
1.8
2.4
0.6
1.2
1.8
2.4
3
3.6
4.2
4.8
5.4
6
FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS
SIMPSON DURA-FLUE DIRECT FLUE GS SYSTEM and
REGENCY DIRECT FLUE SYSTEM (FLEX)
(NG, LPG & ULPG with ULPG Burner)
This diagram shows all allowable combinations of vertical runs with horizontal terminations,
using one 45
o
and one 90
o
elbow
(two 45
o
elbows equal
one 90
o
elbow).
Note: Must use optional flue adapter (Part # 510-994) when using Simpson Dura-Vent pipe. (Refer to page 13.)
• Maintain clearances to combustibles.
• Horizontal flue must be supported every 3 feet.
• Firestops are required at each floor level and whenever passing through a wall.
A flue guard should be used whenever
the termination is lower than the specified
minimum or as per local codes.
Note: Regency Direct Flue System (Flex) is
only approved for horizontal termina-
tions.
Minimum
Simpson Dura-Flue Center-Line
Minimum Flex Kit Center-Line
Min. 30" (762mm)
Max. 24"(0.6m)
0
Vertical Height (M)
0.6
1.2
1.8
2.4
0.6
0
1.8
1.2
2.4
Horizontal (M)
Min. 26 (660mm)
Max. 24"(0.6m)
Vertical Height (M)
0
0.6
1.2
1.8
2.4
Horizontal (M)
0.6
0
1.8
1.2
2.4
Important
If using any Cabinet Mantels with
Part # 510956, 510958, 510962,
510964 and 510834 the wall thimble
must be secured first and flueing
must be attached to unit before
sliding into final position.
Also Simpson Dura-Flue flueing can
-
not be used with any of the mantels
noted above.