20
Regency IP28 Gas Inbuilt Fireplace
INSTALLATION
OPTIONAL WEATHER BOX INSTALLATION
919-192
10/09/12
OPTIONAL WEATHER BOX INSTALLATION
NOTE:
The weather box to be installed ONLY in conjunction with the "Mock Fireplace Kit"
KIT # 456-940 Contains:
456-124
Cover External LH
456-125
Cover External RH
456-128
Cover External Top
456-129
Cover External Bottom
456-130
Cover External Back
440-420F
Plate Gas Line Cover
456-126
Insulation Back
456-127
Insulation Sides
904-643
Screw 10 x 1/2 Hex
2. Attach the top to the sides with 3 screws on
each side.
1. Attach the side to the back with 4 screws on
each side.
3. Attach the bottom to the sides with 3 screws
on each side.
Ensure return edge is on the inside.
4. Install back insulation fi rst, when in place,
bend over 4 securing tabs. Install left and right
sides bending over three tabs each side to
secure.
5. Add gas cover plate, if required.
6. With the weather box assembled, secure to
the outside wall with screws.
7. Ensure weather box is sealed against
weather/water ingress etc
8. Before installing unit, ensure fl ue length, gas
and electrical routing have all been consid-
ered.
9. Install unit.
Side panels attached to back
Attach top to sides
Attach bottom to sides
Tab
Install insulation - secure by bending
tabs
1
IP28