28
Regency IP28 Gas Inbuilt Fireplace
INSTALLATION
OPTIONAL INFILL PANEL INSTALLATION
918-973a
05/02/12
OPTIONAL INFILL PANEL INSTALLATION
If required, an optional infi ll panel is available to cover larger openings.
1.
Remove 2 screws on each side of the unit from locatiions shown below.
2
. Install a mounting bracket on each side of the unit, in the same loca-
tion as where screws removed.
3
. Install 4 support brackets, two on the side, and two on the top of the
unit as shown below.
4
. Hook the infi ll panel onto the brackets installed in Step 2.
NOTE:
Support brackets are only required for masonary installations.
5.
Please see Modular Faceplate instructions to complete installation.
NOTE:
Infi ll panel is required for mock fi replace applications and optional
for masonry applications when installing Modular faceplate.
Top Bracket: Use Front Screw Hole
Side Bracket: Use Back Screw Hole
Infi ll Panel