Regency GF1500LST Gas Fireplace
43
NORMAL OPERATING
SOUNDS OF
GAS APPLIANCES
It is possible that you will hear some sounds from
your gas appliance. This is perfectly normal due to
the fact that there are various gauges and types
of steel used within your appliance. Listed below
are some examples. All are
normal operating
sounds
and should not be considered as defects
in your appliance.
Fan:
Regency gas appliances use high tech fans to
push heated air farther into the room. It is not
unusual for the fan to make a "whirring" sound
when ON. This sound will increase or decrease
in volume depending on the speed setting of your
fan speed control.
Burner Tray:
The burner tray is positioned directly under the
burner and logs and is made of a different gauge
material from the rest of the firebox and body.
Therefore, the varying thicknesses of steel will
expand and contract at slightly different rates which
can cause "ticking" and "cracking" sounds. You
should also be aware that as there are temperature
changes within the unit these sounds will likely
re-occur. Again, this is normal for steel fireboxes.
Gas Control Valve:
As the gas control valve turns ON and OFF, a
dull clicking sound may be audible, this is normal
operation of a gas regulator or valve.
Unit Body/Firebox:
Different types and thicknesses of steel will expand
and contract at different rates resulting in some
"cracking" and "ticking" sounds will be heard
throughout the cycling process.
RESETTING THE UNIT
If the appliance detects a fault and goes into
'lockout', the control system will need to be rest
by depressing the reset button.
The black reset button is located near the bottom
right hand corner of the glass on Side A of the unit.
*Important
: Wait at least 5 minutes for any
unburned gas to clear before resetting the
appliance. Wait 5 minutes between resetting
attempts.
1. Turn the unit ON by either the remote handset
or the man ON/OFF button (bottom, left hand
corner of the glass on Side B of the unit. You
need to hear that both the fans are running.
2) Press and hold down the reset button for
5-10 seconds.
3) The pilot sparks should be heard and seen. It
may take approximately 2-3 seconds for the
flame to light.
4) It may take more than one reset attempt to
ignite the burner. Wait 5 minutes between
attempts, then repeat Steps 1-3.
NOTE:
If the burner fails to ignite within 4-5
attempts, please contact a qualified ser-
vice agent.
operating
instructions
COPY OF LIGHTING PLATE
INSTRUCTIONS
WARNING:
DO NOT SPRAY AEROSOLS IN THE VICINITY OF
THIS APPLIANCE WHILE IN OPERATION.
"
Appliances incorporating a live fuel effect (designed to oper
-
ate with blue flames with slight yellow tips) may exhibit slight
carbon deposition."
FOR YOUR SAFETY READ BEFORE LIGHTING
A) BEFORE LIGHTING smell all around the appliance
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the
floor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance
- Do not touch any electric switch, do not use
any phone in your building
- Immediately call your gas supplier from a
neighbors phone. Follow the gas supplier’s
instructions.
- If you cannot reach your gas supplier, call the fire
department.
B) Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of
the control system and any gas control which has
been under water.
This appliance needs fresh air for safe operation and
must be installed so there are provisions for adequate
combustion and ventilation air.
919-721
WARNING
: If you do not follow these
instructions exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life. Improper
installation, adjustment, alteration, service
or maintenance can cause injury or property
damage. Refer to the owner’s information
manual provided with this appliance. For
assistance or additional information consult
a qualified installer, service agency or gas
supplier.
LIGHTING INSTRUCTIONS
TO TURN OFF GAS APPLIANCE
This appliance must be installed in accordance
with the current AS/NZS 5601
DO NOT REMOVE THIS
INSTRUCTION PLATE
1) Press the ON/OFF button once.
2) Turn off all electric power to the unit if service
is to be performed.
CAUTION
: Hot while in operation. Do not
touch. Severe Burns may result. Due to
high surface temperatures keep children,
clothing and furniture, gasoline and other
liquids having flammable vapors away. Keep
burner and control compartment clean.
See installation and operating instructions
accompanying appliance.
STOP!
Read the safety information above on this
label.
1) Plug the power cord into a power outlet.
2) Press and release the ON/OFF button once to
start the unit.
*
ON/OFF function may be controlled by either
Remote Wall Mount Control or ON/OFF control
on the Unit.
3) After approximately 3 seconds the spark
ignition system will spark for 25 seconds to
light the main burner.
4) If the main burner does not light, check the
gas and reset the unit.
Part #: 919-721
Colours:
Black on Grey, except for parts in RED
Size:
W 2.74" x H 11.94"
Oct. 04/16: created draft
Summary of Contents for GF1500LST-LP
Page 51: ...Regency GF1500LST Gas Fireplace 51 PARTS LIST parts list MAIN ASSEMBLY SIDE A SIDE B ...
Page 53: ...Regency GF1500LST Gas Fireplace 53 NOTES notes ...
Page 60: ......
Page 61: ...Regency GF1500LST Gas Fireplace 61 NOTES notes ...
Page 62: ...62 Regency GF1500LST Gas Fireplace NOTES notes ...
Page 63: ......