48
Regency GF1500LST Gas Fireplace
maintenance
VALVE TRAY REPLACEMENT
PRIOR TO SERVICING THE FAN, ENSURE THAT UNIT HAS COOLED
TO ROOM TEMPERATURE, ALL POWER IS DISCONNECTED AND
GAS SUPPLY IS TURNED OFF.
1. Remove faceplate, inner frame, glass door, front trim piece and end panels
on one side- see instructions in this manual.
2. Remove logs.
3. Remove burner side panels by lifting out as shown in Diagram 1.
4. Remove burner by removing 2 screws in locations shown below.
Diagram 1 - Burner Side Panels
Diagram 2 - Burner Screw Locations
tooltip
tooltip
5. Slide burner to the left and lift out.
6. Remove 12 screws securing valve tray.
7. Lift out valve tray to remove.
8. Replace with new valve tray.
9. Reverse steps 6 through 1 to reinstall new valve tray.
Summary of Contents for GF1500LST-LP
Page 51: ...Regency GF1500LST Gas Fireplace 51 PARTS LIST parts list MAIN ASSEMBLY SIDE A SIDE B ...
Page 53: ...Regency GF1500LST Gas Fireplace 53 NOTES notes ...
Page 60: ......
Page 61: ...Regency GF1500LST Gas Fireplace 61 NOTES notes ...
Page 62: ...62 Regency GF1500LST Gas Fireplace NOTES notes ...
Page 63: ......