Regency GF1500LST Gas Fireplace
19
installation
Flue restriction is required for certain flueing installations, see the
diagrams in the "Flueing
Arrangements" section to determine if they
are required for your installation.
The Flue Restrictor plate is located on the inside top of the firebox.
To set the flue restriction as indicated in the flueing arrangements
diagrams, refer to the following instructions;
1.
Remove one glass door and end panels - see instructions in this
manual.
2.
Remove 10 screws (4 from either side + 2 on the left side - facing
unit)) to remove heat baffle to access restrictor plate.
3.
Remove the screws that hold the flue restrictor in place.
4.
Adjust the flue restrictor plate to the required flue restrictor position
as per the diagrams shown below.
5.
Once the flue restrictor plate is in the required position, secure with
screws.
6. Reassemble unit by reversing Steps 3-1.
FLUE RESTRICTOR SETTINGS
SET 1
SET 0
SET 2
SET 3
Set 0
Fully open
(Factory set)
Set 1 - 50mm
Set 2 - 35mm
Set 3 - 25mm
Screw Positions
Screw Positions
Screw Positions
Screw Positions
Heat Baffle
Summary of Contents for GF1500LST-LP