8
|
Regency
®
E18 Gas Fireplace Insert
|
8
installation
POLICY FOR SOLID FUEL
BURNING &
FACTORY BUILT
FIREPLACES
The Regency
®
E18 may be installed and vented
into any solid fuel fireplace that has been installed
in accordance with the National, Provincial and
local building codes and is constructed of non-
combustible materials.
1.
Installer must mechanically attach the supplied
label to the inside of the firebox of the fireplace
into which the gas fireplace insert is installed.
INSTALLATION
CHECKLIST
1.
Locate your appliance. Refer to the "Clearances
to Combustibles" and "Minimum Fireplace
Clearances" sections.
2.
Make gas and electrical connections. Refer to
the "Gas Connection" section.
Test the pilot. Must be as per diagram in the
"Valve Description" section.
3.
Install Flue Connector. Refer to the "Flue Con-
nector Installation" section.
4.
Install vent. Refer to the "Venting" section.
5.
Test Gas pressure. Refer to the "Gas Pipe
Pressure Testing" section.
Check aeration. Refer to the "Gas Insert Aera-
tion System" section.
"
WARNING
: This fireplace has been converted
for use with a gas fireplace insert only and
cannot be used for burning wood or solid fuels
unless all original parts have been replaced,
and the fireplace re-approved by the authority
having jurisdiction."
Specifications
For Altitude: Natural Gas 0-4500 ft.
Propane:
0-4500 ft.
Burner Orifice Sizes:
Natural Gas Propane
Burner
#44 #55
Max. Input Rating
- Natural Gas
21,600 Btu/h
- Propane
20,500 Btu/h
Min. Input Rating
- Natural Gas
+/-5% 15,000 Btu/h
-Propane +/-5% 17,000 Btu/h
Supply Pressure
Natural Gas
min. 5.0" w.c.
Propane
min. 12.0" w.c.
Manifold Pressure (High)
Natural Gas
3.5" +/- 0.2" w.c.
Propane
10"
+/- 0.2" w.c.
Circulation Fan:
120 VAC, 60 Hz
Variable Speed:
127 CFM, thermally
actived
6.
Test for flue spillage. Refer to the "Test for Flue
Spillage" section.
7.
Install standard and optional features. Refer to
the following sections where applicable:
a. Brick or Enamel Panels
b. Faceplate & Trim
c. Circulation Fan
d. Remote Control
e. Wall Switch
f. Wall Thermostat
8.
Final check. Refer to the "Final Check" section.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and operation fully explained to customer.
This includes:
1.
Clocking the appliance to ensure the correct
firing rate (rate noted on label) after burning
appliance for 15 minutes.
2.
If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.
3.
Ensure that the appliance is venting correctly.
CAUTION: Any alteration to the product that
causes sooting or carboning that results in dam-
age is not the responsibility of the manufacturer.
2.
If the factory-built fireplace doesn't have gas
access hole(s) provided, an access hole of
1-1/2" (37.5mm) or less may be drilled though
the lower sides or bottom of the firebox in a
proper workmanship like manner. This access
hole must be plugged with a non-combustible
insulation after the gas supply line has been
installed.
3.
The fireplace flue damper can be fully blocked
open or removed for installation of the gas
fireplace insert.
4.
The fireplace and fireplace chimney must be
clean and in good working order and constructed
of non-combustible materials.
5.
The chimney cleanouts must fit properly.
6.
Refractory (firebricks), glass doors, screen rails,
screen mesh and log grates can be removed
from the fireplace before installing the gas
fireplace insert.
7.
Smoke shelves, shields and baffles may be
removed if attached by mechanical fasteners.
If any part is removed it must not weaken the
structural integrity of the factory built.
8.
Trim panels or surrounds shall not seal ventila-
tion openings in the fireplace.
9.
Do not cut any sheet-metal parts of the fireplace,
in which the gas fireplace insert is to be installed.
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.
15.
Do not slam shut or strike the glass door.
16.
Under no circumstances should any solid fuels
(wood, paper, cardboard, coal, etc.) be used in
this appliance.
17.
The appliance area must be kept clear and
free of combustible materials, (gases and other
flammable vapours and liquids).
18.
Do not use this appliance if any part has been
under water. Immediately call a qualified ser-
vice technician to inspect the appliance and to
replace any part of the electrical control system
and any gas control which has been under water.
19.
WARNING: Failure to position the
parts in accordance with the diagrams
in this manual or failure to use only
parts specifically approved with this
appliance may result in property
damage or personal injury.
20.
WARNING: Operation of this appliance
when not connected to a properly
installed and maintained venting
system or tampering with the blocked
vent shut-off system can result in
carbon monoxide (CO) poisoning and
possible death.
Summary of Contents for E18-LP
Page 1: ......
Page 74: ...Regency E18 Gas Fireplace Insert 73 73 notes ...
Page 75: ...74 Regency E18 Gas Fireplace Insert 74 notes ...