SEPARATING THE OUTER FIREBOX SHELL FROM INNER FIREBOX
1
. Lay fireplace insert on flat surface (use a drop sheet to protect surface).
2
. Remove Glass Door by removing 2 x Phillips screws at the bottom of Glass Door Frame.
3
. Remove burner by removing 2 x Phillips screws, take note of how aeration adjustment rod is routed.
4
. Remove 2 Phillip screws from top left and right side (Thermodisc bracket).
Remove 2 x 1/4" Hex head screws from top left side and right side of inner firebox.
5
. Remove 4 Phillips crews - 2 per side, located on the bottom base of the firebox. Place
screws and panel brackets aside for reinstallation.
6
. Carefully lift out the inner firebox and set aside until required. Use caution with sleeved
wires on the left side, place inner firebox aside.
7
. Outer firebox shell is ready for installation.
Refer to particular approved appliance in which the E18 is being installed into for the
following:
Existing unit modifications
Adaptor setting
Required flex length
Leg setting / outer shell position both need to be
exact
as measurements indicated.
Outer shell
Before separating Outer Shell and
Unit—Clear wire harness
Aeration adjustment Rod
Burner
Remove screws from these locations
Hex Head
Screws
Phillips
Screws