34
|
Regency
®
E18 Gas Fireplace Insert
|
34
installation
E18 INSTALL SPECIFICATIONS
See Installation of E18 into Existing Units for General Installation Guidance.
This install of the E18 uses
Vent Connection Type A.
The Length of 4" Flex needed is 3" semi-expanded. Secure flue adapter top plate to under side of existing firebox using 4 self taping
screws.
6 15/16"
176mm
6 3/8"
162mm
1 9/16"
40mm
A
36SR Firebox
1 1/2"
37mm
B
36SR Firebox
E18 Insert
DETAIL A
SCALE 1 : 4
Leg height setting
DETAIL B
SCALE 1 : 4
Adaptor Plate
fastener setting
3"
76mm
Montigo 36SR Installation Specifications
Leg Setting / Outer Shell Position
Flex Adaptor Length
Collar Plate Setting / Vent position
6 15/16"
176mm
6 3/8"
162mm
1 9/16"
40mm
A
36SR Firebox
1 1/2"
37mm
B
36SR Firebox
E18 Insert
DETAIL A
SCALE 1 : 4
Leg height setting
DETAIL B
SCALE 1 : 4
Adaptor Plate
fastener setting
3"
76mm
Montigo 36SR Installation Specifications
Leg Setting / Outer Shell Position
Flex Adaptor Length
Collar Plate Setting / Vent position
Right side shown
Set to this
hole
1
. Loosen 2 x philips screws on both right and left legs.
2
. See above diagram below for required leg setting.
3.
Install with supplied phillips screws to prepunched holes and tighten previous screws that were loosened in Step 1.
4
. Keep left side leg loose until outer firebox is in position in ZC box - to allow adjustment of gas line.
Set to this
hole
Secure top plate to firebox w/4 screws.
Secure vent slide plate to flex pipe with 4
screws