48
Regency Bellavista™ B36X Gas Fireplace
WALL SWITCH
(INCLUDED)
1)
Run the supplied 10' of wire through the
right or left side gas inlet opening. Be
careful not to damage wire.
Note: We recommend a maximum of 10'
of wire but if you wish to go with a
longer run, use the Thermostat Wire
Table.
2)
Connect the wire to the wall switch and
install into the receptacle box*. Also attach
wires to the valve as shown below.
*The receptable box (gang box) is not
supplied with the unit. Must be purchased
separately.
CAUTION
Do not wire millivolt
wall switch wire
to 120V wire.
Optional
WALL THERMOSTAT
A wall thermostat may be installed if desired,
connect the wires as per the wiring diagram.
Use table below to determine the maximum
wire length.
Note: Preferable if the thermostat is
installed on an interior wall.
Regency
®
offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.
CAUTION
Do not wire millivolt
wall thermostat wires
to 120V wire.
Thermostat Wire Table
Optional
REMOTE CONTROL
Regency offers 3 different remote control
options which are Pro
fl
ame GT, GTM and GTMF
models. See next page of all available features
of each version.
Use the Regency
®
Remote Control Kit approved
for this unit. Use of other systems may void
your warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
1)
Choose a convenient location on the wall
to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the
fi
replace to
that location. Use Thermostat Wire Table.
CAUTION
Do not wire millivolt
remote control wires
to 120V wire.
2)
See optional remote control instruction
manual for detailed instructions.
INSTALLATION
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
50 Ft.
16 GA.
32 Ft.
18 GA.
20 Ft.
20 GA.
12 Ft.
22 GA.
9 Ft.