Regency Bellavista™ B36XT Gas Fireplace
55
INSTALLATION
18)
Reinstall the logs.
19)
Reinstall glass door and bottom louver / full screen doors.
20)
Plug the light assembly into the receptacle located on the
bottom left side of the unit.
21)
Turn on electrical supply - test lights.
1)
Follow steps 1- 4 from previous page.
2)
Remove 2 screws to remove light diffuser plus gasket.
3)
Replace the bulb - do not touch bulb with bare hands, use gloves or bulb
packaging to protect bulb.
4)
Reinstall the gasket and light diffuser.
5)
Reverse steps 4-1.
Ground Wire
Receptacle
BULB REPLACEMENT
Lockwasher
Fan
ground wire
Nut
#8 Ground Lug
(mobile home
approved)
Star washer
Ground
Green
Neutral
Live
Black
Red
Red
Minimum Convection
Air Temp. Switch
Ground
ON
OFF
Rotary Speed
Control
120V AC
60 Hz
Fan
Optional Fan
Light
Switch
Receptacle
in Unit
To Fan (see above)
Optional Accent Light
Ground
L1
N
Black
Red
Ground
Break Tab
Copper terminals
Black
Do Not Break Tab
on Neutral (silver terminals)
Fan
Switch
Green
ELECTRICAL WORK MUST BE
PERFORMED BY A QUALIFIED
ELECTRICIAN
LINE VOLTAGE WIRING TO RECEPTACLE IN UNIT
TO MAKE OUTLETS INDEPENDENT OF EACH OTHER