Regency Bellavista™ B36XT Gas Fireplace
INSTALLATION
WIRING DIAGRAM
AERATION ADJUSTMENT
LINE VOLTAGE WIRING TO RECEPTACLE IN UNIT
TO MAKE OUTLETS INDEPENDENT OF EACH OTHER
The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue fl ame or
close for a more yellow fl ame.
Minimum Air Shutter Opening:
NG 1/4"
LP 3/8"
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
CAUTION: Carbon will be produced if air shutter
is tightly closed.
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT covered
under warranty.
This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat
will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation, Profl ame GTMF, and light options.
(Do not cut the ground terminal off under any circumstances.)
NOTE:
Even if the fan, GTMF system or light options are not purchased with the unit, it is still a good idea to bring power to the receptacle box (pro-
vided with the unit) in case the optional fan or light is installed at a later date.
Air shutter rod - located to the left
of the valve assembly.
Lockwasher
Fan
ground wire
Nut
#8 Ground Lug
(mobile home
approved)
Star washer
Ground
Green
Neutral
Live
Black
Red
Red
Minimum Convection
Air Temp. Switch
Ground
ON
OFF
Rotary Speed
Control
120V AC
60 Hz
Fan
Optional Fan
Light
Switch
Receptacle
in Unit
To Fan (see above)
Optional Accent Light
Ground
L1
N
Black
Red
Ground
Break Tab
Copper terminals
Black
Do Not Break Tab
on Neutral (silver terminals)
Fan
Switch
Green
ELECTRICAL WORK MUST BE
PERFORMED BY A QUALIFIED
ELECTRICIAN