F5200 Regency Freestanding Woodstove
|
19
19
|
installation
STAINLESS STEEL SMOKE DEFLECTOR INSTALLATION/REPLACEMENT
1.
The stainless smoke deflector is located in the upper front area of the fire-
box (see diagram below). The deflector is held in place with 2 x 7/16” hex
head bolts. Prior to the first fire, ensure deflector is seated properly and
secured with 2 hand tightened bolts.
2.
To replace the deflector, loosen off both 7/16” bolts and slide deflector up-
ward and out. Install new deflector and hand tighten 7/16” hex head bolts.
Ensure positive location of the deflector prior to hand tightening.
WARNING:
Operation of the unit without proper installation of smoke
deflector will void warranty.
3.
Ensure deflector is seated so bolts are situated at the top of the opening
before tightening. Hand tighten bolts only.
4.
Correct Install
: Ensure return edge of smoke deflector is seated within
the backside of the glass wash.
5.
Incorrect Install: Return edge of smoke deflector seated under the glass
wash.