background image

FPI P36-4 Zero Clearance Direct Vent Gas Fireplace

59

WARRANTY

Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit 
thoroughly before it leaves our facility.  FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the  original purchaser of a 
Regency Product. This warranty is not transferable.

The Warranty:  

Limited Lifetime

The combustion chamber, heat exchanger, burner tubes/pans, logs, brick panels and gold plating (against defective manufacture only) are covered under the Limited Lifetime 
Warranty for fi ve (5) years for parts and subsidized labour* and parts only thereafter.

Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for fi ve (5) years and parts only thereafter from date of purchase.

External casting, surrounds and grills are covered against cracks and warps resulting from manufacturer defects, parts and subsidized labour* for three (3) years from the date 
of purchase and parts only thereafter.

Special Finishes - One year on brushed nickel and antique copper full screens and doors. You can expect some changes in color as the product "ages" with constant heating 
and cooling. FPI warranties the product for any manufacturing defects on the original product. However, the manufacturers warranty does not cover changing colors and marks, 
ie. fi nger prints, etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.

Electrical and mechanical components such as blowers, switches, wiring, thermodiscs, FPI remote controls, spill switches, thermopiles, thermocouples, pilot assembly components, 
and gas valves are covered for two years parts and one year subsidized labour* from the date of purchase. Blowers and valves replaced under warranty are considered repairs and 
continue as if new with appliance. ie. twelve (12) months from original purchase date of appliance with a minimum of three (3) months coverage from date of replacement.

FPI venting components are covered parts and subsidized labour* for three (3) years from date of purchase.

Simpson Dura-Vent venting components (Direct Vent units) are covered by Simpson Dura-Vent Inc. warranty.

Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty, valid with a receipt only. Any 
item shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.

Conditions:

Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distributor or agent provided 
that the defective part be returned to the distributor or agent 

Transportation Prepaid,

 if requested.

Porcelain/Enamel - Absolute perfection is neither guaranteed nor commercially possible. Any chips must be reported and inspected by an authorized dealer within three days of 
installation. Reported damage after this time will be subject to rejection.

It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated 
for manufacturer defect.

The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from 
unauthorized service persons or dealers. 

At all times FPI reserves the right to inspect product in the fi eld which is claimed to be defective.

All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer name, 
purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.

Exclusions:

This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim.

At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured. 
ie. as products evolve, fi eld modifi cations or upgrades will not be performed.

FPI will not be liable for travel costs for service work. 

Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the  terms of this warranty policy.

Embers, rockwool, gaskets, door handles and paint are not covered under the terms of this warranty policy.

Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.

The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject  to misuse, improper installation, negligence 
or accident, spillage or downdrafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure caused by mechanical 
systems such as furnaces, fans, clothes dryer, etc.

Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.

FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Performance problems due to operator error will not be covered by this warranty policy.

Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI, may nullify your warranty 
on this product.

Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior facia is not the responsibility of FPI.

* Subsidy according to job scale as predetermined by FPI.

Summary of Contents for P36-LP4 Propane

Page 1: ...xactly a fire or explosion may result causing property damage personal injury or loss of life FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this...

Page 2: ...ide you with all the warmth and charm of a wood fireplace at the flick of a switch The model P36 has been approved by Warnock Hersey for both safety and efficiency As it also bears our own mark it pro...

Page 3: ...the manufacturer s installation instructions and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI N...

Page 4: ...ons 49 MAINTENANCE Maintenance Instructions 49 General Vent Maintenance 49 Log Replacement 50 Thermopile Thermocouple 50 Glass Gasket 50 Door Glass 50 Flush Glass Replacement 50 Removing Valve 51 Inst...

Page 5: ...PI P36 4 Zero Clearance Direct Vent Gas Fireplace 5 5 TABLE OF CONTENTS Finishing Trim 53 PARTS LIST Main Assembly 54 Burner Assembly Log Set 55 Regency Flush Front Accessories 56 WARRANTY Warranty 59...

Page 6: ...Btu h 8 79kW This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 or Natural Gas and Propane Installation Code CSA B149 1 This a...

Page 7: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Page 8: ...8 FPI P36 4 Zero Clearance Direct Vent Gas Fireplace DIMENSIONS UNIT DIMENSIONS 32 1 2 826mm 36 940mm 30 1 2 775mm 12 3 4 324mm 36 914mm 33 1 4 838mm 36 914mm...

Page 9: ...done by a qualified service per son A professional service person should be called to inspect this appliance annually Make it a practice to have all of your gas appliances checked annually 13 Do not s...

Page 10: ...ing the full width and depth of the appliance 4 The P36 Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A B C D See Diagram 1 Note For vent terminat...

Page 11: ...ned from the top surface of the carpeting tile etc Minimum Clearance from Top of Unit to Ceiling from top of unit 32 1016mm Flush Front 6 152mm Full Screen Doors 6 152mm Measured from Surround or Fron...

Page 12: ...12 FPI P36 4 Zero Clearance Direct Vent Gas Fireplace INSTALLATION REGENCY CLEARANCES TRIPOLI ARCH DOOR CLEARANCES Clearances for Flush Front Full Screen Doors Note No Hearth Required...

Page 13: ...SERIES COMBUSTIBLE MANTEL CLEARANCES These drawings are to scale at 1 6 one inch 6 inches Mantel can be installed anywhere in shaded area or higher using the above scale Note Ensure the paint that is...

Page 14: ...mantel clearances are critical Combustible mantel clearances from top of unit are shown in the diagram below Note A non combustible mantel may be installed at a lower height if the framing is made of...

Page 15: ...rch Door a non combustible material 12 305mm above the unit and 6 153mm on each side must be used See diagram 2 For complete framing dimensions see page 57 in this manual The Tripoli Arch Door also re...

Page 16: ...4 36 1 4 12 3 4 46 921mm 921mm 324mm 1168mm D is Minimum height to combustible mate rials including the Minimum 2 51mm Top clearance to the Horizontal Vent 12 3 4 3 1 2 4 2 40 1 2 36 32 1 2 10 dia hol...

Page 17: ...combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney Note These flue pipes must not be connected to any other appliance The gas...

Page 18: ...extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any oth...

Page 19: ...ermination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 screws 8 x 1 1 2 Drill Point Stainless Steel 4 1 6 7 8 dia flexible liner 10 ft length 2 4 dia flexible liner 10 ft length 3 sprin...

Page 20: ...N A N A Adjustable Length 3 10 Galvanized N A N A N A 4DAL N A TC 4DLT Adjustable Length 3 10 Black N A N A N A 4DALB N A TC 4DLTB Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A Adjustable L...

Page 21: ...ontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK N A Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK N A Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHT...

Page 22: ...Wall Installation Wall Thickness inches Vent Length Required inches 4 5 1 2 6 7 8 1 2 9 10 1 1 2 12 9 14 1 2 11 14 5 8 Adj Pipe 15 23 1 2 17 24 Adj Corner Installation Wall Thickness inches Vent Leng...

Page 23: ...diameter 6 7 8 inner diameter Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall NOTE If...

Page 24: ...elbows is required A 0 Min 2 Max B 1 Min 3 Max C 2 Min 4 Max D 3 Min 5 Max E 4 Min 6 Max F 5 Min 7 Max G 6 Min 8 Max Lengths do not include elbow indicated Option V H V V1 H H1 With these options max...

Page 25: ...in 2 Max 1 Min B 1 Min 4 Max 2 Min C 2 Min 5 Max 3 Min D 3 Min 6 Max 4 Min E 4 Min 7 Max 5 Min F 5 Min 8 Max 6 Min Lengths do not include elbow indicated For additional vertical venting with 2 x 90o e...

Page 26: ...learances to combustibles Note Must use optional rigid pipe adaptor when using rigid vent systems Part 510 994 RIGID PIPE VENTING ARRANGEMENTS VERTICAL TERMINATIONS Propane Natural Gas The shaded area...

Page 27: ...s as per the diagram 1 The shaded area in the diagram 1 shows all allowable combinations of straight vertical and offset to vertical terminations with rigid pipe vent systems for Propane and Natural G...

Page 28: ...chimneys may take various contours which the flexible liner will accommodate However keep the flexible liner as straight as possible avoid unnecessary bending The Air Intake pipe must be attached to...

Page 29: ...ded area in the diagrams show the allowable vertical terminations 8 Min 40 1 2 30 Max 30 Horizontal Distance Feet Vertical Height feet 2 max VENTING ARRANGEMENTS VERTICAL TERMINATION with Co linear Fl...

Page 30: ...rocedure Four indenta tions located on the female ends of pipes and fittings are designed to slide straight onto the male ends of adjacent pipes and fittings by orienting the four pipe indentations so...

Page 31: ...n the vent pipe and the vent cap by attaching the two sheet metal strips extending from the vent cap assembly into the outer wall of the vent pipe Use the two sheet metal screws provided to connect th...

Page 32: ...o Offset Chart DIRECT VENT SYSTEM FLEX INSTALLATION PROCEDURES 1 Locate the unit in the framing rough in the gas preferably on the right side of the unit and the electrical Junction block is on the le...

Page 33: ...tu h Minimum Output with blower Off 11 500 Btu h Supply Pressure min 5 0 w c Manifold Pressure High 3 8 0 2 w c Electrical 120 V A C System Circulation Fan variable speed 130 CFM Log Set Ceramic fibre...

Page 34: ...closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kPa Disconnect piping from valve at press...

Page 35: ...910 037 LPG Injector Pilot Orifice 1 918 481 Instruction Sheet 5 Remove the 2 screws holding the Burner Assembly to the firebox base Push the Burner Assembly to the left and lift out DC Sparker Kit Co...

Page 36: ...and connect it to the DC Sparker Piezo Ignitor Ignitor Wire Piezo Ignitor Ignitor Wire DC Sparker 18 Reverse steps 6 1 Fig 1 11 Remove the black protection cap by hand from the hi low knob Fig 1 Fig...

Page 37: ...and outlet pressures 37 Check operation of flame control 38 Check for proper flame appearance and glow on logs NOTE The battery in the DC Sparker Box will need to be replaced an nually 25 Locate the g...

Page 38: ...in the unit 2 Insert the back brick panel first by carefully slipping it between the back wall of the firebox and the rear log bracket 3 Put the side panels in next Slide them in from the front and pu...

Page 39: ...miculite j 946 669 Platinum Embers supplied w packaged manual 4 Place Log 02 51 on the front right side of the burner Push the back of the log against the 2 brackets with the notch on the bottom right...

Page 40: ...front brackets with the notch on the bottom of the log fitting into the first grate tab Notch 02 55 02 50 02 54 5 Position Log 02 53 across the cutouts in Logs 02 49 and 02 51 with the notch on the l...

Page 41: ...and on the indentation on Log 02 54 The bottom right end sits behind the rear grate tab 10 Place the embers on the front of the burner tray in the places shown on the photo Separateplatinumembersandp...

Page 42: ...The standard flush door comes with a black frame To install the frame simply hook the top door flange onto the top of the unit and swing the door towards the unit see Diagram 1 Be careful that the gl...

Page 43: ...SWITCH OPTIONAL 1 Run the wire through the right or left side inlet opening Be careful not to damage wire Note We recommend a maximum of 15 of wire but if you wish to go with a longer run use the Ther...

Page 44: ...ptional remote control thermostat will continue to operate However a 120V A C power supply is needed for the fan blower operation Do not cut the ground terminal off under any circumstances NOTE Even i...

Page 45: ...use by stove fan only 120 Volts 60 Hz Copper Ground White Neutral Black Hot P36 E lectrical Connection Alternative Scheme B Power at Switch Wall Junction Box Speed Control S witch with lead wires Wire...

Page 46: ...36 4 Zero Clearance Direct Vent Gas Fireplace INSTALLATION For PROPANE Units and Units Equipped with DC Spark Boxes For installation of the DC Spark Box refer to the LP Conversion instructions in this...

Page 47: ...ainst the valve tub ing Diagram 1 8 Secure the two boxes together with one screw 10 Remove the control box assembly and push the hold downclipontothelouver Bend the tab until it is at 90o to the louve...

Page 48: ...ses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process IMPORTANT Gas on off knob cannot be turned from PILO...

Page 49: ...the flames are steady not lifting or floating If there is a problem call a qualified service person 5 The appliance and venting system must be inspected before use and at least annually by a qualifie...

Page 50: ...h 3 Disconnect thermocouple by loosening nut from the valve with a 9mm wrench Dis connect thermopile by loosening 2 screws marked TP on the valve 4 Drop the thermocouple or thermopile down from the br...

Page 51: ...m wrench 6 Reconnect the pilot tube nut with a 7 16 wrench 7 Scrapeofftheoldgasketfromthefloorofthe firebox and from the valve tray assembly 8 Install a new gasket and reinstall the valve tray assembl...

Page 52: ...er has a hinge that is attached 2 screws per hinge to the lip on bottom of the unit 3 Open the bottom louver Pull the Burner ON OFF control box from inside the bottom of the fireplace and position the...

Page 53: ...rim with the holes in the firebox side 2 Secure with 2 screws per side 3 Loosen the 3 screws in the top inside edge of the firebox 4 Slide the Finishing Trim Top over the Side Trim pieces and fit the...

Page 54: ...ick Panel Back 34 Brick Panel Left 35 Brick Panel Right 511 031 Brick Clips each 432 967 Burner On Off Switch Assy 38 910 241 Switch Burner On Off 910 899 Wire Harness Valve to Burner 432 917 F a n A...

Page 55: ...b 56 910 190 Piezo Ignitor 57 910 478 SIT Valve NG LPG 58 Valve Bracket 59 Firebox Base 66 910 038 Pilot Assy S I T 3 Flame NG 910 039 Pilot Assy S I T 3 Flame LP 67 Pilot Holder 68 W840470 Pilot Asse...

Page 56: ...ers Gold Black 510 922 Flush Louvers Black 510 923 Flush Louvers Steel Black 133 Flush Louver Assy Top 134 Flush Louver Assy Bottom 135 940 090 P Glass Flush 136 936 155 Glass Gasket Tadpole 904 691 U...

Page 57: ...FPI P36 4 Zero Clearance Direct Vent Gas Fireplace 57 NOTES...

Page 58: ...58 FPI P36 4 Zero Clearance Direct Vent Gas Fireplace NOTES...

Page 59: ...gent Transportation Prepaid if requested Porcelain Enamel Absolute perfectionisneither guaranteednor commercially possible Any chips must be reported and inspected by an authorized dealer within three...

Page 60: ...r your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and spe...

Reviews: