LRI3E-11 / HRI3E-11 Direct Vent Gas Insert
| 33
installation
BRICK PANEL INSTALLATION
Important: This appliance cannot be operated without brick (LRI3E-11 only), enamel panels (HRI3E-11/LRI3E-11) or
painted panels (HRI3E-11 only) installed.
919-706
08.30.16
1
LRI3E
BRICK PANEL INSTALLATION
Brick panels are soft and fragile. Use caution when handling the panels,
being careful not to jar them or scratch the painted surfaces.
tooltip
tooltip
tooltip
1. Carefully unpack brick panels.
2. Install back brick panel - place against back wall of firebox, the side panels
(once installed) will secure the back panel in position.
Install back brick panel
Install left brick panel
Install right brick panel
Final install
3. Loosen bracket screw in firebox in location shown below, slide left brick
panel into position until it contacts the back panel. Slide the panel bracket
on from the front of the unit and tighten the bracket screw.
4. Loosen bracket screw in firebox in location shown below, slide right brick
panel into position until it contacts the back panel. Slide the panel bracket
on from the back of the unit and tighten the bracket screw.