Regency Horizon HZ54E-1 Gas Fireplace
23
INSTALLATION
H
H1
V
V1
H1
H
V
Horizontal Venting with Two (2) 90
o
Elbows
NG and LP
Horizontal Venting with Three (3) 90
o
Elbows
NG and LP
One 90
o
elbow = Two 45
o
elbows.
Option V
H V + V1 H + H1
A)
2' Min. 1' Max. 3' Min. 2' Max.
B)
2' Min. 2' Max. 5' Min. 4' Max.
C)
3' Min. 2' Max. 7' Min. 5' Max.
D)
4' Min. 3 Max. 9' Min. 6' Max.
E)
5' Min. 4' Max. 10' Min. 7' Max.
F)
6' Min. 6' Max. 11' Min. 9' Max.
With these options, max.
total pipe length is 30 feet
with min. of 11 feet total
vertical and max. 9 feet total
horizontal.
Please note min. 1 foot
between 90
o
elbows is
required.
VENT RESTRICTOR SETTING:
Vent restrictor factory set at Set 1, no adjustment required.
One 90
o
elbow = Two 45
o
elbows.
Option
V
H + H1
With these options,
maximum total pipe
length is 30 feet with
minimum of 6 feet total
vertical and maximum
10 feet total horizontal.
A)
2' Min.
4' Max.
B)
3' Min.
6' Max.
C)
4' Min.
8' Max.
D)
5' Min.
9' Max.
E)
6' Min.
10' Max.
Please note minimum 1 foot between 90
o
elbows is
required.
VENT RESTRICTOR SETTING:
Vent restrictor factory set at Set 1, no adjustment
required.