38
Regency Horizon HZ54E-1 Gas Fireplace
INSTALLATION
BATTERY & ON | OFF SWITCH INSTALLATION
DFBC
= digital fi replace burner control
1)
Remove glass door and valve cover (see valve cover removal
section in this manual) to access to DFBC & battery pack.
2)
Lift DFBC and battery pack up and out.
3)
Disconnect connector from battery holder and remove from tray –
(battery holder is attached by Velcro to tray).
4)
Install - 4 AA batteries, reconnect the connector to the battery pack and
put back onto Velcro strip
5)
Locate the Green and White from the DFBC module wire harness;
connect the spade connectors from the On/Off switch. Green to Black
and White to White.
6)
Reinstall the module and battery pack tray into the holder