Regency Horizon® HZ40E-11 Gas Fireplace
|
5
safety decal
This is a copy of the label that accompanies each HZ40E-NG11 and HZ40E-LP11 Direct Vent Gas Fireplace. We have printed a copy of the contents here
for your review.
NOTE:
Regency
®
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
Copy of Safety Decal
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible con-
nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
Part #:
920-002a
Colour:
Black on grey except what is indicated as being printed red.
Size:
(File at 100%) 9.318’’W x 5.892’’H
Material:
2 ml silver matt polyester (DPM SMS)
Dec. 17/18:
Created draft
Jan. 22/19:
Rev A - Remodeled decal and added ETL logo at the bottom
*
Printer
: Start serial sequence @ 00200001
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER CETTE ÉTIQUETTE
502
502
DOOR SEAL: Please
check that the door is
properly sealed
FPI Fireplace Products International Ltd. Delta, BC, Canada
Minimum Clearances to Combustibles /
Dégagements minimaux par rapport aux matériaux combustibles
Serial No./ No de série
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
.
Fan (Part # 258-917)/Ventilateur (pièce n°258-917)
Electrical supply / Alimentation électrique 115VAC, 1.13 A, 60Hz.
Made in Canada/ Fabriqué au Canada
Duplicate S/N
(
See Instruction Manual for
detailed instructions)
APPAREIL FONCTIONNANT AU GAZ PROPANE
Modèle HZ40E-LP11
PROPANE GAS: Model HZ40E-LP11
APPAREIL FONCTIONNANT AU GAZ NATUREL
Modèle HZ40E-NG11
5.0" WC/C.E. (1.25 kPa)
3.5" WC/C.E. (0.87 kPa)
1.6" WC/C.E. (0.40 kPa)
# 40 DMS
26,000 Btu/h (7.61 kW)
18,000 Btu/h (5.28 kW)
0-4500 ft/pi (0-1372 m)
11" WC/C.E. (2.73 kpa)
10" WC/C.E. (2.49 kPa)
6.4" WC/C.E. (1.59 kPa)
# 53 DMS
25,500 Btu/h (7.47kW)
21,000 Btu/h (6.15 kW)
0-4500 ft/pi (0-1372 m)
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Maximum input
Minimum input
Altitude
D
E
F
A
B
C
Side Walls/Murs latéraux
A
8” (203mm)
Ceiling/Plafond
B 22” (559mm)
Min. Mantel Height/Hteur min.
manteau
C
17" (432mm)
Max. Mantel Depth/Prof. max.
manteau
D
13” (330mm)
Alcove Width/Largeur alcôve
E
84" (1524mm)
Alcove Depth/Prof. alcôve
F
36" (2134mm)
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si
ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les
règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil n'est pas convertible pour une utilisation avec d'autres gaz, sauf si une trousse certifiée est utilisée.
This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
DOIT ÊTRE UTILISÉ UNIQUEMENT AVEC LES PORTES VITRÉES CERTIFIÉES AVEC
L'APPAREIL
For Use Only with Barrier (Part # 258-013) Follow installation instructions. Utiliser uniquement avec un écran de protection (n°258-013). Suivre les consignes d'installation.
Pression d'alimentation minimale
Pression de sortie (manifold) - basse
Pression de sortie (manifold)
- max.
Taille de l’orifice
D bit calorifique maximal
é
D bit calorifique minimal
é
Altitude
Pression d'alimentation minimale
Pression de sortie (manifold) - basse
Pression de sortie (manifold)
- max.
Taille de l’orifice
D bit calorifique maximal
é
D bit calorifique minimal
é
Altitude
NOT FOR USE WITH SOLID FUELS. / NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE.
Listed/Nom:
VENTED GAS FIREPLACE HEATERS / APPAREIL DE CHAUFFAGE AU GAZ À ÉVACUATION.
Certified to/Certifi :
é
ANSI Z21.88-2017 • CSA-2.33-2017
CSA 2.17-2017
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek.
NATURAL GAS: Model HZ40E-NG11
C #: 4001172
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Maximum input
Minimum input
Altitude
920-002a
CSA P.4.1 Fireplace Efficiency (FE) /Efficacité énergétique des foyers (EEF) CSA P.4.1
Natural Gas / Gaz naturel 64.44%
Propane Gas / Gaz propane 66.75%
CANADIAN ENERGY
PERFORMANCE
VERIFIED
RENDEMENT
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
Decal Location
Remove Faceplate (see manual for instructions)
with the faceplate removed, the rating plate will
be located on the left hand side of the unit. It will
be located in-between the inner and outer firebox
(see picture).
DO NOT REMOVE DECAL FROM UNIT.
Summary of Contents for Horizon HZ40E
Page 71: ...Regency Horizon HZ40E 11 Gas Fireplace 71 notes ...
Page 76: ...76 Regency Horizon HZ40E 11 Gas Fireplace warranty ...
Page 77: ...Regency Horizon HZ40E 11 Gas Fireplace 77 notes ...
Page 78: ...78 Regency Horizon HZ40E 11 Gas Fireplace notes ...