64 |
Grandview® G600EC Gas Fireplace
installation
LP Conversion
for G600EC using SIT 885 NOVA Gas Valve
G600EC
1
09.21.20
920-303
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
Each Kit contains one LP Conversion Kit
Conversion Kit #776-969 Contains:
Qty. Part #
Description
1
904-977
Burner Orifice #55
1
904-529
5/32" Allen Key
1
918-590
Decal "Converted
to LPG"
1
908-528
Red "LP" label
1
910-037
LP Injector (Pilot
Orifice)
1
911-011
Stepper Motor
1
920-303
Instruction Sheet
Installation of LP
Conversion Kit:
10. Re-install pilot cap and pilot retainer clip.
11. Remove burner orifice with a 3/8"
wrench. Use another wrench to hold on
to the elbow behind the orifice. Discard
orifice.
7. Remove the pilot retainer clip below the
pilot cap.
9. Unscrew the pilot orifice with the Allen key;
then replace with the LPG pilot orifice,
provided in the kit.
Pilot retainer clip
8. Pull off the pilot cap to expose the pilot
orifice.
Diagram 2: Slide burner assembly to the
right—then remove.
6. Remove three screws then remove the
burner assembly.
12. Reinstall new burner orifice LPG
stamped #55 and tighten.
LP Conversion
G600EC using SIT 885 NOVA Gas Valve
13. Remove the bottom cover panel by rotat-
ing it up and lifting it out.
14. Pull the IFC box towards the front of the
unit.
1.
Shut off the gas and electrical supply.
2. Remove the safety screen*.
3. Remove the glass door*.
4. Remove the logs, glass, and any other
media*.
5. Remove the two log supports (4 screws)
and the grate assembly (2 screws).
Diagram 1: Remove 6 screws.