Grandview® G600EC Gas Fireplace
| 65
installation
G600EC
920-303
2
09.21.20
19. Reverse steps 17-13 to reinstall IFC
board. Reinstall burner assembly.
20. Adjust aeration accordingly—see
manual for details.
21. Attach the label “This unit has been
converted to LPG” near or on top of the
serial # decal.
22. Replace yellow “NG” label with red “LPG”
label.
23. Check for gas leaks.
24. Check inlet and outlet pressures.
25. Check operation of flame control.
26. Reverse steps 4-1.
18. Remove regulator and discard. Install
the Hi/Lo pressure regulator onto the
valve with 2 screws as shown below and
also reconnect new cable from pressure
regulator motor disconnected in step 19.
Installer Notice:
These instructions must
remain with the appliance.
15. Rotate the front of the IFC box up and pull
it out of the unit.
16. Remove the two screws that secure the
cover plate to the base of the IFC box,
then remove the cover plate.
17. Disconnect the cable coming from the
pressure regulator motor at the IFC
board (marked X6 on the IFC).
Cable from motor
LP Conversion