F2450M Regency Freestanding Woodstove

  |    

11

installation

Minimum Overall Depth (Y) of Floor Protector - Corner Hearth
Reference only when hearth pad is installed to rear wall at minimum pipe clearances.

Hearth Depth

F2450M

L

M

N

O

Residential Installation ''C'' Vent (Single Wall)

Canada

33-11/16" (856mm)

62-7/8" (1596mm)

52-1/8" (1324mm)

28-5/16" (727mm)

USA

33-11/16" (856mm)

60-7/8" (1545mm)

50-3/4" (1289mm)

26-7/8" (681mm)

Residential Close Clearance (To be installed with required pipe components)

Canada

33-11/16" (856mm)

60-1/16" (1527mm)

50-1/8" (1273mm)

26-5/16" (676mm)

USA

33-11/16" (856mm)

58-1/16" (1475mm)

48-3/4" (1238mm)

24-7/8" (610mm)

M

O

L

N

Z

16"

Y

X

for

angled

corners

6"

6"

W

W

Floor Protection (Corner Installation)

A combustible floor must be protected by non-combustible 
material (like tile, concrete board, or certified to UL-1618 or 
as defined by local codes) extending beneath the heater and 
a minimum of 8" (203mm) from each side and minimum 16" 
(406mm)** from the front face of the stove and minimum 6" 
(152mm)** (or the rear clearance to combustibles whichever 
is smaller) from the rear of the stove. 

When installed with horizontal venting, non-combustible floor 
protection must beneath the flue pipe and extend 2" (51mm) 
beyond each side.

    Minimum Overall Width (X) of Floor 
       Protector

 

for all installations: 

 Stove 

F2450M 

33-11/16" (856 mm)

 

**NOTE: In Canada, floor protection must extend 18" (450mm) to 

the front and 8" (203mm) to back of the stove.

Minimum Overall Depth (Y) of Floor Protector

Unit

Residential

"C" Vent

From Edge of Fuel Door 

Opening

Y

Z

W

Medium F2450M

Canada - 49" (1245mm)
USA -      47" (1194mm)

 **6" (152mm)

8" (203mm)

Summary of Contents for Classic F2450M

Page 1: ...ding Woodstove F2450M 04 21 21 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference Owners Installation Manual Tested by www regency fire com French Manual Download https bit ly 3rAsDW7 Manuel en Français https bit ly 3rAsDW7 ...

Page 2: ...peration It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual CAUTION BURNUNTREATEDWOODONLY OTHERMATERIALSSUCHASWOODPRESERVATIVES METALFOILS COAL PLASTIC GARBAGE SULPHUR OR OIL MAY DAMAGE THE STOVE This heater is designed to burn natural wood only Higher efficiencies and lower emissions generally result when burning air dr...

Page 3: ...Installing Outside Air Using Bottom Heat Shield Legs 17 Recommended Heights For Woodstove Flue 18 Optional Outside Air Kit 19 Brick Installation 20 Wood Handle Door Assembly 21 Flue Baffle Secondary Air Tube Installation 22 Fan Installation 23 Stainless Steel Smoke Deflector Installation 24 Operation Seasoned Firewood 25 Operating Instructions 25 Draft Control 25 First Fire 26 Fan Operation 27 Ash...

Page 4: ...de and back of the stove DO NOT REMOVE THIS LABEL NE RETIREZ PAS CETTE ÉTIQUETTE 512 INSTALLANDUSEONLYINACCORDANCEWITHTHEMANUFACTURER SINSTALLATIONANDOPERATINGINSTRUCTIONS CONTACTLOCALBUILDINGORFIREOFFICIALSABOUTRESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA USE 150 MM 6 IN DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED UL103 HT FACTORY BUILT CHIMNEY SUITABLE FOR ...

Page 5: ... 3 16 817mm 34 5 8 879mm 27 1 8 690mm 24 13 16 630mm 6 7 16 163mm 33 7 8 860mm 31 7 16 798mm 7 13 16 198mm 21 1 4 540mm 21 1 2 546mm 23 1 8 587mm from fuel door opening Rear Front Rear 4 9 16 115mm 6 13 16 173mm Images for OUTSIDE AIR DIMENSIONS Rear Front 4 9 16 115mm Images for OUTSIDE AIR DIMENSIONS ...

Page 6: ...y the chimney connector must be at least 24 gauge steel Do not use galvanized pipe For Mobile Home installation refertotheMobileHomeinstallationinstructions within this manual 12 DO NOT CONNECT THIS UNIT TO A CHIM NEY SERVING ANOTHER APPLIANCE 13 A chimney connector cannot pass through an attic or roof space closet or similar concealed space or a floor ceiling wall or partition of combustible cons...

Page 7: ...ar heat deflector is installed on top of the rear heat shield as shown in Diagram 4 Side Shield Adjustment The left and right side shields are lowered for ship ping and handling It allows for a handhold on the top of the stove Before placing the stove in its final position the side shields must be raised Loosen the screws on the rear on the stove 3 per side slide the side panel up as far as possib...

Page 8: ... the legs to the stove if the stove is tipped on its back preferably on a soft surface to prevent scratching Ensure to be extremely careful when tipping stove Important Prior to installing the bottom heat shield remove the 4 inch blanking plate See below This must be removed for combustion air to enter the ap pliance 1 Removethe4boltsfromundersideofthebaseofthepedestal and discard Also remove cove...

Page 9: ... air A F F C C B E D NOTE Be aware that local Codes and Regulations may override some clearances listed in this manual Check with your local inspector NOTE This clearance is also required for air space between the appliance and wall ceiling Residential Installation C Vent Single Wall Unit From Unit From Corner From Flue Center Line A B C D E F Medium F2450M with Airmate 16 406mm 9 5 241mm 8 203mm ...

Page 10: ...16 856mm 8 203mm Residential Close Clearance To be installed with required pipe components Unit A B C D F2450M with Airmate Canada 48 1219mm 18 457mm 33 11 16 856mm 8 203mm USA 46 1168mm 16 406mm 33 11 16 856mm 8 203mm F2450M with Rear Deflector Canada 50 1270mm 18 457mm 33 11 16 856mm 8 203mm USA 48 1219mm 16 406mm 33 11 16 856mm 8 203mm C B D A D Minimum Alcove Clearance and Clearance to Combust...

Page 11: ...llation A combustible floor must be protected by non combustible material like tile concrete board or certified to UL 1618 or as defined by local codes extending beneath the heater and a minimum of 8 203mm from each side and minimum 16 406mm from the front face of the stove and minimum 6 152mm or the rear clearance to combustibles whichever is smaller from the rear of the stove Wheninstalledwithho...

Page 12: ...try with the minimum required height and then if problems do arise add additional height at a later date 4 Slide the roof flashing over your chimney and seal the flashing to the roof with roofing compound Secure the flashing to your roof with nails or screws 5 Place the storm collar over the flashing sealing the joints with a silicone caulking 6 Fasten the raincap with spark screens if required to...

Page 13: ...alled and operated When connect ing the stove through a combustible wall to a masonrychimney specialmethodsareneeded Ensure that an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the structure Masonry Fireplace There are listed kits available to connect a stove to a masonry fireplace The kit is an adapter that is installed at the locatio...

Page 14: ...combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with a minimum 24 gage 024 61 mm 6 152 4 mm metal chimney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separatio...

Page 15: ...f exit for a height up to 7ft 2130mm 6 Thechimneyshallbeattacheddirectlytotheroom heater and shall extend at least 3 ft 914mm above the part of the roof through which it passes The top of the chimney should project at least 2ft 610mm above the highest elevation of any part of the Mobile Home within 10 ft 3048mm of the chimney 7 The chimney system shall comply with Local Requirements 8 Any openings...

Page 16: ...ecure flex to the Mobile Home box 7 Secure pedestal base and Mobile Home Box to firebox as shown in diagram 3 using the screws that were previously removed loosened in step 1 See pedestal instructions The Mobile Home Box and firebox use the same screws Diagram 4 8 Install blanking plate to the front of the pedestal with 4 screws 1 Lay unit on its back Remove two front 7 16 bolts Loosen rear two 7 ...

Page 17: ...l with 4 screws Use picture from step 8 16 Install the mandatory outside air kit See Mobile Home Instal lation section in this manual Place unit into its final position to complete install Installing Outside Air Using Bottom Heat Shield Legs Page 1 of 1 075 500 SLDASM 12 19 2016 Mobile Home Box Square Transition Box Collar Bottom Heat Shield Cast legs Knock out Blanking plate 17 Remove knock out f...

Page 18: ...0 0 18 0 22 5 4000 5000 14 0 15 0 16 0 17 5 21 0 18 5 23 0 5000 6000 14 5 15 5 17 0 18 0 21 5 19 0 24 0 6000 7000 15 0 16 0 17 5 18 5 22 5 20 0 25 0 7000 8000 15 5 16 5 18 0 19 0 23 0 20 5 25 5 8000 9000 16 0 17 0 18 5 20 0 24 0 21 0 26 5 9000 10000 16 5 17 5 19 0 20 5 24 5 22 0 27 0 NOTE No more than two offsets four elbows allowed Two 45o elbows equal one 90o elbow WARNING DO NOT INSTALL IN SLEE...

Page 19: ...e fresh air into the pedestal area by using a minimum 4 duct pipe with a mesh grill at the outside termination Outside Air Through Pedestal Rear Remove the blanking plate from the rear of the pedestal and bend the two tabs out 90 degrees Pipe fresh air into the pedestal area by using a minimum 4 metallic duct pipe with a mesh grill at the outside termination Fasten the pipe to the cover plate usin...

Page 20: ...n their correct positions Do not use a grate NOTE The AD brick in the drawings above is the brick covering the Ash Dump hole that is used when the Ash Drawer Kit is installed refer to the Listed Components for Mobile Home Installation section LyTherm sheet Order of firebrick install a Rear Firebrick b Firebox floor install brick over LyTherm Sheet c Right and left side Firebricks 70 AD 70 70 70 74...

Page 21: ...oor is not creating a tight seal a washer can be removed Recheck door to ensure there is still a tight seal Repeat steps if door seal is still not tight until a tight seal has been achieved The handle should be approximately in the 8 o clock position when door is fully closed Diagram 3 2 Place the door onto the hinges and then place the door handle through the opening on the door as shown in Diagr...

Page 22: ...2 air tubes on the floor of the firebox 1 Open the door and remove stainless steel smoke deflector See smoke deflector instructions in this manual 2 Remove the front secondary air tube with pliers as shown below 4 Install the 2 front secondary air tubes with pliers and hammer to lock them into place as shown below 3 Tilt the left baffle up on top of the side channel and it will leave enough room t...

Page 23: ...usly the thermo switch sensor is not making contact with the stove body Remove the fan bend the bracket closer to the stove and re install the fan MANUAL To manually operate the fan system push the bottom switch to MAN and the top switch to either HIGH or LOW This will bypass the sensing device and allow full control of the fan Switching from AUTO to MAN or HIGH to LOW may be done anytime CAUTION ...

Page 24: ...sen off both bolts and slide defector upward and out Install new deflector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector installed with 2 bolts Note This is a view from the back of the unit through the top Smoke deflector is installed through t...

Page 25: ...on of dryness but may not be a reliable indicator Some wet wood has checks and some dry wood has no checks The wood tends to darken from white or cream colour to grey or yellow as it dries Two dry pieces banged together sound hollow wet pieces sound solid and dull Dry wood weighs much less than wet wood Split a piece of wood If the exposed surface feels damp the wood is too wet to burn Seasoned Fi...

Page 26: ...aintbecomesseasoned Windows and or doors should be left open to provide adequate ventilation while this tem porary condition exists Burning the stove at a very high temperature the first few times may damagethepaint Burnfiresatamoderatelevel the first few days 6 Do not place anything on the stove top during the curing process This may result in damage to your paint finish 7 During the first few da...

Page 27: ...ild up in the chimney system Check and clean chimney at regular intervals Failure to do so can result in a serious chimney fire 8 YourRegencystovecanbeveryhot Youmaybe seriously burned if you touch the stove while it is operating keep children clothing and furniture away Warn children of the burn hazard 9 Thestoveconsumesairwhileoperating provide adequate ventilation with an air duct or open a win...

Page 28: ...Salt drift wood Cut lumber plywood mill ends Kiln dried wood Classic Door Handle Replacement Glass Replacement Your Regency stove is supplied with 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce In the event that you break your glass by impact purchase your replacement from an authorized Regency dealer only Remove the door from the stove and remove the ...

Page 29: ...am ceramicglass Part 846 306 thatwillwithstandthe highest heat that your unit will produce In the event that you break your glass by impact purchase your replacement from an authorized Regency dealer only and follow our step by step instructions for replacement refer to Glass Replacement section Allow the stove to cool down before cleaning the glass Cleaning the glass will prevent build up of carb...

Page 30: ...Replace any damaged parts Adjust door catch assembly If unable to obtain a tight seal on the door replace door gasket seal Readjust door catch after new gasket installed Inspect condition and seal of Glass Gasket Door Gasket Perform paper test replace gasket if required Paper Test Test the seal on the loading door with a paper bill Place a paper bill in the gasket area of the door on a cold stove ...

Page 31: ...air tubes vermiculite baffles as per page 22 2 Loosen the two 7 16 bolts nuts to remove replace vertical deflector 3 Repeat steps to install new vertical deflector NOTE ENSURE THAT VERTICAL DEFLECTOR IS PUSHED UP AS FAR AS POSSIBLE TIGHT TO TOP OF FIREBOX Vertical Deflector Remove 2 front air tubes Slide left down to remove Reverse to replace ...

Page 32: ... 8 Window Adhesive Sold per foot 4 Feet required 14 075 077F Glass Retainer 15 021 973 Door Handle Assembly Complete 16 948 079BN Hinge Cap Brush Nickel Each 17 948 146 Long Black Handle 18 850 241 Black Door Complete 18 850 243 Black with Nickel Accent Door Complete 19 846 515 Fan Assembly Complete 20 910 138 2 Way Switch 21 910 140 3 way Switch 22 850 105 Airmate 23 075 051 SS Slide Holder 8 075...

Page 33: ...F2450M Regency Freestanding Woodstove 33 parts list 7 8 22 3 6 4 2 18 13 1 14 17 12 11 16 19 20 21 ...

Page 34: ...eat Shield 43 942 110 Ashplug 44 820 249 Ashplug Tool 45 021 024 Blanking Plate N S 904 100 5 16 x 5 1 2 Long Hex Head Bolt Each N S 820 468F Metal Washer N S 820 456 Metal Spacer Support Bracket Each 45 44 42 43 41 40 51 52 50 53 Part Description 50 021 915 Pedestal Complete 51 075 069 Pedestal Door 52 904 257 Magnetic Catch Each 53 075 910 Ashdrawer N S 904 023 5 16 x 1 1 2 Hex Head Bolt Each Ba...

Page 35: ...D 70 70 70 74 72 72 76 020 960 Brick Kit Complete 70 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 72 Brick Partial 1 1 4 x 2 x 4 1 2 74 Brick Partial 1 1 4 x 4 1 2 x 3 1 2 76 Brick Partial 1 1 4 x 2 x 9 NOTE This kit contains one spare brick in case of breakage ...

Page 36: ...razing 1 Catalyst Combustor 10 Years Prorated Venting Chimney 1 Screens 1 See specific warranty details in regards to the catalyst combustor in unit manual Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at ...

Page 37: ...incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs kiln dried wood lack of regular ma...

Page 38: ...idental or consequential damages so the above limitations or exclusions may not apply to you Customers located outside the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain all warranty and service In the event the authorized ...

Page 39: ...n order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases mad...

Page 40: ...40 F2450M Regency Freestanding Woodstove warranty ...

Page 41: ...F2450M Regency Freestanding Woodstove 41 notes ...

Page 42: ...42 F2450M Regency Freestanding Woodstove notes ...

Page 43: ...F2450M Regency Freestanding Woodstove 43 dimensions ...

Page 44: ...omplete the following information Dealer Name Address ____________________________________ ________________________________________________________ Installer _________________________________________________ Phone _________________________________________________ Date Installed ____________________________________________ Serial __________________________________________________ ...

Reviews: