City Series ACV60E
|
41
installation
Description
Simpson
Direct Vent Pro
®
Rigid Pipe Adaptor (when using DuraVent) for 127 mm x 203 mm
flueing only. Must choose if venting with rigid pipe.
770-994
High Wind termination cap (cowl)
58DVA-VCH
Galvanized Wall Thimble
58DVA-WT
Ceiling Firestop Galvanized 127 mm - 203 mm
58DVA-FS
Galvanized PIpe - 152 mm Length
58DVA-06
Galvanized PIpe - 304 mm Length
58DVA-12
Galvanized PIpe - 609 mm Length
58DVA-24
Galvanized PIpe - 914 mm Length
58DVA-36
Galvanized PIpe - 1219 mm Length
58DVA-48
Galvanized PIpe - 1524 mm Length
58DVA-60
Galvanized PIpe - 45 Degree Elbow
58DVA-E45
Galvanized PIpe - 90 Degree Elbow
58DVA-E90
127 mm x 203 mm Rigid Pipe Cross Reference Chart When Using Simpson DuraVent
Components from different Manufacturers cannot be mixed. Not all rigid pipe components are available directly from FPI.
Description
Simpson
Direct Vent Pro
®
*Selkirk
Direct Temp™
*Metal-Fab™
Sure Seal
*ICC Excel
Direct
*Olympia
Ventis DV***
Attic Insulation Shield 12"
58DVA-IS*
N/A
N/A
N/A
VDV-AIS05
High Wind Vertical Cap
58DVA-VCH
N/A
N/A
TM-5VT
VDV-VCH05
High Wind Horizontal Cap
N/A
N/A
N/A
TM-5DHT
N/A
Horizontal Square Termination Cap
N/A
5DT-HHC
5DHT
TM-5HT
VDV-HC05
Vertical Termination Cap
N/A
5DT-HVC
5DVT
N/A
N/A
Storm Collar
58DVA-SC
5DT-SC
5DSC
TM-SC
VDV-SC05
Restrictor Disk
N/A
N/A
N/A
N/A
N/A
Colinear Flex Connectors
N/A
N/A
N/A
N/A
N/A
Adjustable Flashing 0/12-6/12
58DVA-F6
5DT-AF6
5DF
TF-5FA
VDV-F0506
Adjustable Flashing 6/12-12/12
58DVA-F12
5DT-AF12
5DF1-2
TF-5FB
VDV-F0512
Vinyl Siding Standoff
58DVA-VSS
5DT-VS
5DVS
TM-VSS
VDV-SSO
Vinyl Siding Shield Plate
N/A
5DT-VSP
N/A
N/A
N/A
Snorkel Termination 14"
58DVA-SNK14
N/A
N/A
TM-5ST14
N/A
Snorkel Termination 36"
58DVA-SNK36*
N/A
N/A
TM-5ST36
N/A
Basic Horizontal Termination Kit (A
)
N/A
5DT-HKA
N/A
TM-5HTK
VDV-KW05
Horizontal Termination Kit (B)
58DVA-KHA
5DT-HKB
N/A
TM-5HTK
VDV-K05
Vertical Termination Kit
58DVA-VHA
5DT-VKC
N/A
N/A
N/A
FPI
946-604/P
Simpson Direct Vent or Astro Cap -Vent Guard (Optional)
946-623/P
AstroCap XL Horizontal Cap
770-994
Rigid Pipe Adaptor (Must use with all rigid piping)
**946-506/P
Vent Guard (Optional)
**946-606
Starter collar reducer 5" x 8" to 4" x 6-5/8" (B36XTE, B36XTCE ONLY)
946-625
Vinyl Siding Standoff - AstroCap XL
Note:
When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (5DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (770-994).
**
Not available/applicable for the following units: B41XTE, B41XTCE, CB60E, CV60E, CV72E, HZ54E, U1500E
Offset Pipe Selection:
Use this table to determine offset pipe lengths.
Pipe Length
(L)
127 mm
x
203 mm
v
enting
For specific instructions on venting components - visit the
manufacturers website listed below.
Run (X)
Rise (Y)
0
mm
1
44
mm
389
mm
Simpson Direct Vent Pro: www.duravent.com
152
mm
224
mm
468
mm
229
mm
278
mm
5
22
mm
3
05
mm
330
mm
576
mm
610
mm
697
mm
789
mm
Note:
Horizontal runs of vent must be level, or have a
6 mm
rise for every
305 mm
of run towards the termination.
Never allow the vent to run downward - this could cause high
temperatures and may present a possible fire hazard.
914
mm
757
mm
1002
mm
1219
mm
972
mm
1216
mm
* Not available from Regency
***Olympia Ventis DV applicable for the following units only when using 5" x 8" vent system: B36XTE, B 36XTCE, B41XTE, B41XTCE, CB60E, CV60E, CV72E, U1500E