32
|
City Series ACV60E
installation
Chase Vent Installation (White Front)
Framed opening must be between 76 mm and 89 mm tall, and at least 1530 mm wide to accommodate the chase vent.
The top of the chase vent opening must be 51 mm or less from the top of the chase enclosure.
920-325
12.23.20
1
CITY SERIES
ACB60E/ACV60E CHASE VENT INSTALLATION (WHITE FRONT)
Max
51 mm
Ceiling
Ceiling
Top of chase enclosure
Max
51 mm
Stud
Stud
Stud
Stud
1524 mm
Chase Vent
1524 mm
Chase
Screw to studs here
Vent
Finishing material
Finishing material
Opening for vent
76 mm-89 mm
Min
1530 mm
Chase
v
ent is installed after finishing material.
Framed
o
pening must be between
76 mm
and
89 mm
tall and at least
1530 mm
wide to accom
m
odate
the
c
hase vent.
The top of the chase vent opening must be
51 mm
or less from the top of the chase
enclosure.