![Regency Fireplace Products CB40EPV-LP Owners & Installation Manual Download Page 74](http://html.mh-extra.com/html/regency-fireplace-products/cb40epv-lp/cb40epv-lp_owners-and-installation-manual_1433869074.webp)
74
|
City Series CB40EPV
installation
Vertical Inline Power Vent Terminations
Flex Pipe
Diagram 4
20. Put a bead of caulking on the exterior between the outer pipe and
flashing to prevent water from penetrating the chimney system.
21. Slide storm collar over pipe length until it reaches the flashing.
22. Install termination cap by twist locking it.
23. Secure the flashing to the roof using screws
Note
: Any closets or storage spaces which the vent passes through
must be enclosed.
Diagram 3
Diagram 3a
Diagram 3b
19. Slide the finished length up towards the flashing ensuring the length
of pipe is a minimum of 2 feet (0.61 m) measured from the top of the
roof. Level the chimney and secure using the roof support provided
with kit to bottom side of the roof as shown using a minimum of 2
screws per side- see Diagram 3b. See Diagram 4 for roof pitch and
height requirements. See Diagram 3a for securing method if 2 ft.
(0.61 m) is insufficient and additional lengths are required, this may
be purchased separately. See Simpson Duravent components list in
the instruction manual for part numbers.
Flex Pipe
Ceiling Firestop
Roof Support / Brace
Flashing
Storm Collar
Termination Cap
Ceiling Firestop
Inline Power Vent Terminal
Inner Pipe Adaptor (shown inside flex pipe)
Enclosure
Flex Pipe
Ceiling Firestop
Roof Support
Flashing
Elbow Support
Termination Cap
Storm Collar
Ceiling Firestop
Support to prevent sagging
Inline Power Vent Terminal
Enclosure
Ceiling firestop
Flashing
Termination Cap
Storm Collar
Roof support
Ceiling firestop
Roof Pitch
Minimum
Vent Height
Feet Meters
flat to 7/12
2
0.61
over 7/12 to 8/12
2
0.61
over 8/12 to 9/12
2
0.61
over 9/12 to 10/12
2.5
0.76
over 10/12 to 11/12
3.25
0.99
over 11/12 to 12/12
4
1.22
over 12/12 to 14/12
5
1.52
over 14/12 to 16/12
6
1.83
over 16/12 to 18/12
7
2.13
over 18/12 to 20/12
7.5
2.29
over 20/12 to 21/12
8
2.44