background image

-7-

12. Make sure that the dispensing valve is securely tightened onto the water

bottle.

13. Place the water bottle on the base of the distiller chassis. The base of the

distiller chassis has raised edges to assist in positioning the water bottle properly.

NOTE:

Do not remove the water bottle while the distiller is running.

14. At the end of the distillation cycle (about 4 to 4

1

2

hours), the distiller will

shut off automatically and the “start” light will go out. The fan will continue

to  operate  for  several  minutes.  Let  the  distiller  cool  completely  before

removing the boiling chamber from the chassis.

15. Unplug cord from wall outlet when not in use.

NOTE:

Approximately 8 ounces (240 ml) of water will remain in the boiling

chamber  at  the  end  of  the  distillation  cycle.  This  feature  reduces  scale

deposits in the boiling chamber .

CAUTION: To prevent personal injury, burn and/or scald injury, do not

remove the boiling chamber while the start button is illuminated or

at any time when the boiling chamber is hot. Always unplug the distiller

from the wall outlet and allow the boiling chamber to cool completely

before removing it from the distiller.

NOTE:

The water bottle has been designed to hold one gallon (4 liters)

of water and to provide enough space so that the carbon filter does not

remain in contact with the distilled water . Therefore, the water bottle will

not fill completely.
Once the distillation cycle is complete, the water bottle may be placed in

the refrigerator and used to dispense the distilled water. The filter may be

left in the water bottle or removed and stored until the next cycle of the

distiller is run. Secure the cap onto the water bottle to avoid spilling. The

cap must be opened slightly before dispensing water. It is recommended

that the water bottle NOT be placed in a freezer as the handle may become

brittle and crack.

CLEANING INSTRUCTIONS

CAUTION: To prevent personal injury or electric shock, do not immerse

the distiller, its boiling chamber, cord or plug in water or other liquid.

Do not use alkaline cleaning agents when cleaning. Use a soft cloth

and mild detergent.

BOILING CHAMBER
Rinse the boiling chamber after every distillation cycle once the unit has

cooled completely

.

Remove the baffle by unscrewing its securing nut. Inspect

the baffle for scale deposits. Half fill the boiling chamber with tap water , agitate

and discard the water. The water may be drained through the spout. Securely

reinstall the baffle and securing nut.

Summary of Contents for W 10000 series

Page 1: ...To prevent personal injury or property damage read and follow the instructions and or warnings in this use and care guide COUNTERTOP WATER DISTILLER Model No W 10000 Series USE CARE GUIDE ...

Page 2: ...le of reducing many impurities which can be found in tap water With minimum maintenance your distiller will provide convenient trouble free operation Distillation naturally dependable Using nature s own design for recycling water distillation reduces impurities through the process of evaporation and condensation As the water is heated it turns into vapor which rises leaving most impurities behind ...

Page 3: ... Water Bottle 4 Sanitize the Water Bottle 4 Prepare the Carbon Filter 4 5 Instructions For Making Distilled Water 5 7 Cleaning Instr uctions Boiling Chamber 7 8 Water Bottle 8 Outside Sur faces 8 Carbon Filter 8 Troubleshooting Guide 8 10 Warranty and Customer Service Information Back Cover 1 ...

Page 4: ...w the boiling chamber to cool before removing it from the distiller Do not let the cord touch hot surfaces or hang over the edge of a counter or table Do not use the distiller if it or its cord is damaged or not working pr operly Return the unit to your authorized distributor for examination and or repair Avoid using extension cords Your distiller its boiling chamber cord and plug should not be im...

Page 5: ...that it will not drape or hang over the edge of a countertop or tabletop where it can be pulled on by childrenortrippedover To preventelectricshock injury orfire theelectrical rating of the extension cord you use must be the same as or more than wattageofthedistiller wattageisindicatedonthebottomofthedistiller Plug distiller into rated voltage AC grounded electric outlet ONLY rated voltage found o...

Page 6: ...quids other than distilled water Liquids other than distilled water may transfer a taste or odor to the water bottle TO SANITIZE WATER BOTTLE Add 4 3 4 ounces 150 ml of 3 hydrogen peroxide solution H2O2 to the water bottle Fill the bottle with hot 160 F 71 C distilled or tap water Do not install the carbon filter at this time Cap the water bottle and shake the vigorously Let stand for twenty minut...

Page 7: ...AC electrical outlet ONLY 2 Remove the boiling chamber from the distiller by grasping its handle and pulling it straight out of the distiller chassis Do not lift up when pulling the boiling chamber out of the chassis CAUTION To prevent personal injury burn and or scald injury do not remove the boiling chamber until i t has cooled completely 3 Remove the boiling chamber s cap by turning it counterc...

Page 8: ...ydamagetheboilingchambermust be fully engaged prior to start up 9 Press the start button at the base of the boiling chamber NOTE Thebuttonwillglowwhentheboiling chamber is heating however the light will go out and the boiling chamber will stop heating if electrical power to the boiling chamber is interrupted or stopped If this occurs press the start button again to restart the distillation cycle 1...

Page 9: ...the distiller NOTE The water bottle has been designed to hold one gallon 4 liters of water and to provide enough space so that the carbon filter does not remain in contact with the distilled water Therefore the water bottle will not fill completely Once the distillation cycle is complete the water bottle may be placed in the refrigerator and used to dispense the distilled water The filter may be l...

Page 10: ...ttle OUTSIDE SURFACES Use a common household glass or appliance cleaner or a damp soft cloth to cleanthedistiller soutsidesurfaces Donotuseabrasiveorsolventbasedcleaners Do not spray cleaning products directly onto the distiller Thedistiller scoolingsystemvents seediagramonpage4 shouldbevacuumed occasionally or cleaned with a soft brush to remove dust and debris Failure to do so may cause the dist...

Page 11: ...in the Assure that this fitting is spout of the boiling tightened before each use chamber The baffle must be installed with the flat side down this means that the hole is down and the narrow end inser ted into the spout of the boiling chamber See page 6 The distiller is not in a well Distiller must be operated in ventilated area a well ventilated area for proper heat dissipation Machine is equippe...

Page 12: ... chassis so that both the boiling chamber and the electrical connection are tightly joined See page 6 The o ring is damaged or If damaged replace o ring missing from the baffle Make sure the o ring is properly placed on the baffle fitting in the circular groove See page 6 The flat gasket between Replace gasket the boiling chamber spout and baffle is missing or damaged ...

Page 13: ...ur authorized distributor for all warranty parts and service needs For additional information call Consumer Service at 262 626 8623 Regal Ware Inc 1675 Reigle Drive Kewaskum WI 53040 USA Printed in USA 2006 Regal Ware Inc ...

Reviews: