Commissioning
44 — English
Variomat 1 — 06.07.2016 – Rev. B
Pre-selected time for a make-up cycle. Upon expiry of this set time, the system interrupts
the make-up and returns the "Make-up time" fault message.
Max. make-up time
010 min.
If the set number of make-up cycles is exceeded within two hours, the system interrupts
the make-up and returns the "Make-up cycles" fault message.
Max. make-up cycl.
003 / 2 h
yes:
FQIRA+ contact water meter is installed, see chapter 4.6 "Optional equipment and
accessories" on page 13 .
This is the prerequisite for the make-up quantity monitoring and the operation of a
softening system.
With water meter
YES
no:
A contact water meter is not installed (standard model).
Only displayed if "YES" has been set in the "With water meter" menu option.
•
Use "OK" to delete the counter.
– Press "YES" to reset the value displayed to "0".
– Press "No" to retain the displayed value.
Make-up quantity
000020 l
This value is only displayed if "YES" has been set in the "With water meter" menu option.
•
When the set quantity is exceeded, the system interrupts the make-up process and
returns the error message "Max. make-up quantity exceeded".
Max. make-up qty.
000100 l
This value is only displayed if "YES" has been set in the "With water meter" menu option.
With softening
YES
yes:
The system offers more queries regarding the softening process.
no:
The system does not offer more queries regarding the softening process.
This value is only displayed if "YES" has been set in the "With softening" menu option.
Lock make-up?
YES
yes:
The system stops the make-up process when the set soft water capacity is exceeded.
no:
The system does not stop the make-up process. The system displays the "Softening"
message.
This value is only displayed if "YES" has been set in the "With softening" menu option.
•
Hardness reduction is calculated from the difference of the overall water hardness
GH
actual
and the target water hardness GH
target
.
– Hardness reduction = GH
actual
-GH
target
l °dH
Enter the value in the controller. Consult the manufacturer information for third-party
products.
Hardness reduction
10 °dH