Konformitätserklärung der Steuerung/ 

Declaration of conformity of the control unit

Wir/We 

                                        

            

Reflex Winkelmann GmbH & Co. KG
Gersteinstraße 
D- Ahlen

erklären, daß das Produkt:/

declare, that this product:

Geräteart/Device type:

WANACH
Nachfüllstation für Heizungssysteme/
Water make-up unit for heating systems

Typenbezeichnung/
Model identification:

WANACH - 4 .0 
(-0.00)
ab Herstelldatum/
of date of manufacturing: 0.0.00

mit der EWG-Richtlinie /6/EEC und 004/0/EEC (EMV-Direktive) sowie / EWG 
(Niederspannungsrichtlinie) und den daraus resultierenden Normenanforderungen konform ist.

is in compliance with the EWG regulation 89/336/EEC and 2004/108/EEC (EMV directive) as well as 
73/23 EWG (low voltage directive) and the resultant standard requirements.

Technische Vorschriften/Technical regulations:

Niederspannungsrichtlinie/Low voltage directive

EN 600-:00-0

Prüfbericht Nr./Inspection report no.: ECL-SAF-TR-0-0-V0.00

Prüfinstitut (Labor)/Inspection body (inspection institiute):                                          Herberg Service Plus GmbH, Nürnberg

EMV-Richtlinie/EMV directive

EN 04- und 04- (Category 4)

Prüfbericht Nr./Inspection report no.: ECL-EMC-TR-0-4-V0.00

Prüfinstitut (Labor)/Inspection body (inspection institiute):                                          Herberg Service Plus GmbH, Nürnberg

Anmerkungen/Annotations:

 Das Original des Prüfberichts liegt bei emz vor./ 

   The original document of the inspection report are available at emz.

 Da es sich um eine Einbaukomponente handelt, wurden alle Messungen in der bestimmungsgemäßen  

   Anwendung im Gesamtgerät der Fa. Sasserath durchgeführt bzw. betrachtet./
  
All tests according to the destinated operation purposes within the complete device have been carried out and observed  
  by the company Sasserath.

 Dies ist keine Konformitätserklärung für das Gesamtgerät./ 

  This is no declaration of conformity for the complete device.

Ahlen, 0.0.00

Ort und Datum der Ausstellung

Franz Tripp 

Geschäftsführer/ 
Managing director 

reflex ’påfyllningsstation’ 

Konformitätserklärung/Declaration of conformity

Summary of Contents for fillcontrol

Page 1: ...reflex fillcontrol reflex p fyllningsstation Water make up device Installation Drift och sk tselanvisningar Installation operation and maintenance instructions Stand Status 04 06...

Page 2: ...lectrical connection 7 Terminal connection diagram 7 Initial start up Prerequisites for initial start up 8 Steps of initial start up 8 System dependent setting 8 9 Pressure reducer setting 9 10 Parame...

Page 3: ...us Access menus Quit error messages Upp ner val knappar Up Down operation selection buttons 1 Avst ngning Shut off 2 Tryck givare Pressure sensor 3 Kontroll panel Control Control panel 4 Motor kulvent...

Page 4: ...cal data are provided on the type plate or the markings on the valve Make sure to fully comply with the service parameters of tempera ture and pressure protection do not remain under these values and...

Page 5: ...off system separator type BA acc to DIN EN 1717 tundish dirt trap mano meter connections motor operated ball valve control unit pressure sensor manometer and pressure reducer acc to DIN EN 1567 Adjus...

Page 6: ...the connecting pipe of the reflex fillcontrol make sure that stagnation is excluded The down stream pipe has to be passed in a way length nominal width that the the loss of pressure in this pipe is 0...

Page 7: ...power supply Kopplings schema Terminal connection diagram Givare Transducer Tryckgivare 3 pols anslutning PH Str mf rs rjd tryckgivare Jord tryckgivare Signal tryckgivare fr nh gertillv nster Pressure...

Page 8: ...ometern har blivit installerad p reduceringsventilen fabriks monterad fr n approx 06 06 Installation reflex fillcontrol is completed The connection on the water side of the system and to the refill wa...

Page 9: ...e knappen igen i 4 sekunder s kommer lysdiod I Tryck blinka var 0 5 sekund Det inst llda trycket visas nu i displayen f r att st lla in r tt v rde p0 s f r man justera det genom att trycka p ner eller...

Page 10: ...fyllningstiden verstiger tv timmar tror systemet att det finns ett l ckage och ett felmeddelande kommer fram i displayen S 12 Under systemets fyllningstid skall trycket kvarst S 8 Drift vervakningen...

Page 11: ...low the setting value if the second value is exeeded reflex fillcontrol is turned off p 8 During the LED Auto is green and at the same time the LED IV is red The operation time and the number of cycle...

Page 12: ...ppen i 3 sek E3 Auto blinkar r tt Osannolikt tryck signal och eller motorn terg r inte till noll l ge och eller internt systemfel ROM och eller internt systemfel EE Flera Olika Informera Reflex servic...

Page 13: ...nande vatten Kolla s att O ringen och t tningarna r intakta reng r eller byt ut om det r n dv ndigt Underh ll reduceringsventil Reduceringsventilen m ste testas med j mna mellanrum minst en g ng per r...

Page 14: ...rating conditions but after one year at the latest The connections available for ball valves allow a functionality test of the device to be carried out with an adequate pressure gauge Dirt trap Isolat...

Page 15: ...r Inspection report no ECL SAF TR 05 071 V01 00 Pr finstitut Labor Inspection body inspection institiute Herberg Service Plus GmbH N rnberg EMV Richtlinie EMV directive EN 55014 1 und 55014 2 Category...

Page 16: ...ical modifications Reflex Winkelmann GmbH Co KG Gersteinstrasse 19 59227 Ahlen Germany Telefon 49 23 82 70 69 0 Telefax 49 23 82 70 69 588 www reflex de Somatherm AB Bang rdsgatan 1 Box 900 671 29 ARV...