Safety

•  Read the following safety information carefully before attempting to 

operate or service the meter.

•  To avoid damages to the instrument do not apply the signals which 

exceed the maximum limits shown in the technical specifications tables.

•  Do not use the meter or test leads if they look damaged. Use extreme 

caution when working around bare conductors or bus bars.

•  Accidental contact with the conductor could result in electric shock.
•  Use the meter only as specified in this manual; otherwise, the protection 

provided by the meter may be impaired.

•  Read the operating instructions before use and follow all safety Information.
•  Caution when working with voltages above 60V DC or 30V AC RMS. 

Such voltages pose a shock hazard.

•  Before taking resistance measurements or testing acoustic continuity, 

disconnect circuit from main power supply and all loads from the circuit.

Safety Symbols: 

Caution
Refer to this manual before using the meter.

Dangerous voltages.

Meter is protected throughout by double insulation or rein

-

forced insulation.

When servicing, use only specified replacement parts.
CE Comply with EN-61010-1

For service on this or any other REED product, contact REED Instruments 
at [email protected].

 

REED Instruments

1-877-849-2127 | [email protected] | www.reedinstruments.com

Summary of Contents for ST-5500

Page 1: ...reedinstruments www com Model ST 5500 Digital Insulation Tester Instruction Manual REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Page 2: ...k the test leads 7 Battery replacement 7 Measurements 7 8 Insulation Resistance Measurements 7 Low Resistance Measurements 8 AC DC Voltage Measurements 8 Power Tool Small Appliances 9 Motors 9 Cables...

Page 3: ...may be impaired Read the operating instructions before use and follow all safety Information Caution when working with voltages above 60V DC or 30V AC RMS Such voltages pose a shock hazard Before tak...

Page 4: ...k 200M 250V 200M 500V 2000M 1000V 750V ACV 1000V DCV Sampling Rate 2 5 times per second Zero Adjustment Automatic adjustment Over Range Indicator Number 1 of highest digit is displayed Low Battery Ind...

Page 5: ...urrent 200mA DC Voltage Range Resolution Accuracy Input Impedance Overload Protection 1000V 1V 0 8 3 10M 1000Vrms AC Voltage 40Hz 400Hz Range Resolution Accuracy Input Impedance Overload Protection 75...

Page 6: ...lack lead into the COM terminal 2 On 200 and ACV Range Connect the red test lead into the V terminal and the black lead into terminal COM How to check the test leads Set the range select switch to the...

Page 7: ...t have at least fifty outlets an outlet being a switch socket lighting point etc A switched socket counts as one outlet The minimum accept able insulation resistance is 1M For a large installation the...

Page 8: ...ton Set the LOCK button to lock test voltage pressing it again will turn the tester off Low Resistance Continuity Measurements 1 Set the range switch to 200 Position 2 Connect the red test lead to the...

Page 9: ...the motor wire and all other components be tween the motor and the main switch If a weakness is in dicated the mo tor and other components should be checked individually If the motor is disconnected...

Page 10: ...ecting one megohmmeter lead to a ground and or lead sheather and the other megohmmeter lead to each of the conductors in turn Check insulation resistance between conductors by connecting megohmmeter l...

Reviews: