background image

Ground 

Resistance 

Tester

Instruction 

Manual

R5700

 

REED Instruments

1-877-849-2127 | [email protected] | www.reedinstruments.com

Summary of Contents for R5700

Page 1: ...Ground Resistance Tester Instruction Manual R5700 REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Page 2: ...s 8 10 Power ON OFF 8 Auto Power OFF 9 Resistance Measurement Mode 9 Current Measurement Mode 9 10 Data Hold Memory Storage 10 11 Memory Recall 11 Setting the Critical Alarms 12 Battery Replacement 12...

Page 3: ...er the manufacturer s warranty Servicing should only be provided by an authorized service center Be aware of your surroundings environment and measurement scope If the instrument applies to ground res...

Page 4: ...stores up to 99 readings User adjustable alarms Data hold function Durable double molded conductor clamp 1 26 32mm jaw size for large ground rods Low battery indicator and auto shut off Cat III 300V s...

Page 5: ...00 to 880 900 to 1200 Accuracy 0 010 to 0 099 1 0 01 0 10 to 0 99 1 0 01 1 0 to 49 9 1 0 1 50 0 to 99 5 1 5 0 5 100 to 199 2 1 200 to 395 5 5 400 to 590 10 10 600 to 880 20 20 900 to 1200 25 30 Resolu...

Page 6: ...lay Backlit LCD Yes User Selectable Alarms Yes Display Hold Yes Internal Memory Yes up to 99 data points Autoshut Off Yes after 5 minutes Power Supply 4 x AA Batteries Over Range Indicator Yes Low Bat...

Page 7: ...nternal Memory Full Indicator 4 Data Inquiry Indicator 5 Number of Stored Values 6 Current Voltage Measurement Indicator 7 Resistance Measurement Indicator 3 4 5 R5700 Ground Tester 8 Noise Signal Ind...

Page 8: ...asses Refer to Resistance Measurement Mode for details Note The instrument automatically enters the resistance measurement mode at start up regardless of the last saved setting 4 If the instrument doe...

Page 9: ...that you can now measure the resistance 2 Pull the trigger to open the clamp and clamp onto the calibration loop being measured 3 The LCD will display the resistance value 4 If the instrument beeps an...

Page 10: ...e OL A as show below Data Hold Memory Storage The instrument has the capability of storing up to 99 values Stored values are not lost when instrument is turned on or off 1 While taking a measurement p...

Page 11: ...memory recall mode and the first stored value will be displayed 2 Press the and arrows to scroll through the stored values 3 To clear the stored values press the SAVE and buttons simultaneously Note I...

Page 12: ...will begin to beep if the measured vale exceeds the selected alarm 7 Follow steps 1 to 6 to set the critical alarm in mA Battery Replacement When the icon appears on the LCD display you will need to r...

Page 13: ...or by email at info reedinstruments com to discuss the claim and determine the appropriate steps to process the warranty Product Disposal and Recycling Please follow local laws and regulations when di...

Page 14: ...Test Measure with Confidence Check out our latest Products REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Reviews: