Concealed Wiring Option:
It is recommended that the concealed wiring adaptor be installed
before
the wall cladding is in position.
1. Cut plug from end of electrical flex (if applicable)
2. Carefully remove the stainless steel leg from the flex
3. Thread the flex through the centre of the stainless steel foot
4. Connection to electrical supply should be carried out by a qualified electrician in accordance with local electrical
requirements and regulations and to ensure the electrical supply, plug & switch location, and product location will
comply with your local regulations
.
5. Installation of the adaptor first requires mounting the bottom feet of the towel warmer followed by the top feet. Do
not turn on the power to the towel warmer until installation is complete.
6. Ensure that the flush box that the towel warmer will be wired to is within this distance of the mounting position of the
foot of the towel warmer that has the flex. Allow for loss of flex length due to connections.
7. Drill a 13mm hole into the face of the stud where the towel warmer foot with the flex is to be positioned. Drill the
hole approximately 25mm deep.
8.
Identify the side of the stud facing the flush box that the towel warmer will be wired to. On that side of the stud, drill
a 25mm deep hole at right angles to this first hole so that the hole will break into the base of the first hole. Refer to
Fig1.
9. Place a pull through line from the flush box to the 13mm hole that can be picked up later once the wall cladding is in
place
10. Once the wall cladding is positioned, remove some of the cladding to expose the 9mm hole. Locate the pull through and
thread the adaptor-fixing barrel onto the pull through.
11. Screw the adaptor-fixing barrel into the stud. On masonry walls drill a 10mm hole and epoxy resin the adaptor-fixing
barrel into position. The shoulder of the barrel should leave a gap equal to the wall cladding thickness so that when the
wall cladding is fixed the shoulder of the barrel is flush with the wall cladding. (refer Fig 2)
12.
Measure the towel warmers horizontal distance between the mounting barrel centers. Mark a point horizontally from the
centre of the adaptor at this measurement for your model (but check the actual measurements to your warmer as
manufacturing tolerances apply) for the other bottom fixing barrel. It is important that the line between these two points is
level
.
13. Screw the other fixing barrel (provided with the towel warmer) into place with the screw provided with the towel warmer.
14. Attach the pull through to the flex and pull the flex through the stud holes to the flush box.
15. Position the towel warmer on the bottom two fixing barrels and mark the two top feet. (Use easy to remove pencil)
16. Mark the centre distance for the top fixing barrels (per above) & screw the fixing barrels to the wall.
17. Remount the towel warmer on the four fixing barrels. Secure the foot containing the flex with the screw provided then