X-IP-SERIES USER MANUAL
6
3.2.1 SUPPLY
VOLTAGE
3.2.1.1 INPUT
VOLTAGE
Mains input: 110V/230V @ 0.5A
3.2.1.2 OUTPUT
VOLTAGE
Output @ Camera connector: 24Vdc @ 3A nominal
3.2.2
RVIP-PSU-ALM INTERNAL CONNECTIONS
3.2.2.1
MAINS POWER INPUT
3.2.2.2
CAMERA CONNECTION
6 Way Terminal Block
PCB IDENT
MAINS POWER
*
LIVE
LIVE (BROWN) 110/230Vac Connection via 2 way terminal block
*
NEUTRAL
NEUTRAL (BLUE) Connection via 2 way terminal block
*
EARTH
GREEN/YELLOW Connection via terminal screw
NOTE: Earth connection requires 4mm red spade loop (supplied with PSU) to be fitted by engineer at installation.
S
SA
AFFE
ET
TY
Y:: E
EN
NS
SU
UR
RE
E M
MA
AIIN
NS
S IIN
NP
PU
UT
T &
& E
EA
AR
RT
TH
H C
CO
ON
NN
NE
EC
CT
TIIO
ON
NS
S A
AR
RE
E S
SE
EC
CU
UR
RE
EL
LY
Y S
ST
TR
RA
AIIN
N R
RE
EL
LIIE
EV
VE
ED
D..
PIN NO.
PCB IDENT
WIRE COLOUR
SIGNAL
1
TxN
Blue
PSU TxN / Camera RxN
2
TxP
Blue / White
PSU TxP / Camera RxP
3
RxN
Orange
PSU RxN / Camera TxN
4
RxP
Orange / White
PSU RxP / Camera TxP
5
24V
Red
6
GND
Black
NOTE: Signal names depend on context, TxN (Transmit Data Negative) for the camera is RxN
(Receive Data Negative) for the PSU or Alarm Unit.
3.2
REDVISION IP POWER SUPPLY WITH ALARM MODULE (RVIP-PSU-ALM)
WARRANTY & SAFETY NOTICE:
DISCONNECT ALL POWER BEFORE
OPENING OR WORKING ON THE
RVIP-PSU-ALM16 POWER SUPPLY
UNIT WITH EMBEDDED ALARM
CARD. THIS PROTECTS HIGH
VOLTAGE COMPONENTS.
INSTALLATION MUST BE CARRIED
OUT BY A SUITABLY QUALIFIED
PERSON.
FIXING
POINTS x4
ALARM/WASH/
AUX RELAY
OUTPUTS
ALARM
CONFIG
SWITCHES
ALARM
INPUTS
CAMERA
CONNECTION
NETWORK
CONNECTION