34 | Troubleshooting
Input Over Voltage
The Alternator or Trickle-Charge Input is too high voltage, or the total voltage rating of
connected solar panels is too high.
1.
Check the voltage rating of auxiliary products and make sure that they do not exceed
the limits of each input. See
'Electrical Specifications' (page 38)
2.
Unplug overrated items one-by-one until the fault resolves.
3.
If connected, check that solar panels are suitably rated for use with the GoBlock.
4.
If connected, disconnect solar panels one-by-one until the fault resolves.
Input Reverse Polarity Detected
Connected auxiliary items may be wired incorrectly (i.e. wired 'backwards').
1.
Check for reverse polarity in the wiring of connected loads by disconnecting them one
at a time until the fault resolves.
2.
Discontinue use of any accessories that cause an
'Input Reverse Polarity Detected' alert.
Output Overcurrent
The combined current rating of connected loads exceeds 50 A, i.e. There may be too
many loads plugged in.
Priority is given to the Fridge Socket.
1.
Disconnect one or more of the loads until the fault resolves.
Battery Level Critically Low (< 5%)
The GoBlock's Battery level is less than 5%.
1.
Charge the GoBlock.