Power
Receptacle
The switch requires a positive voltage between
18 and 30 VDC
. Make the power
connections as shown in the diagram below.
Power
Receptacle
Location
Power
Receptacle
Pinout
Recommended
Plug
Model #
D38999/26WA98SA
(w/ socket contacts and A keying)
10.
Note:
The W in the above recommended plug specifies cadmium plating. However, you
may choose a different plating to meet your requirements. The MIL receptacles on the
switch have black nickel plating which is RoHS compliant.
--
DC Supply
++
C
B
A
No Connection
Receptacle:
Shell=A, Insert=98, Contacts=P, Keying=A