Section 3
Power and Communication Connections
Overview
The switch features 38999 Series III style connectors which meet or exceed the MIL-STD-
38999 standard. All these connectors have EMI shielding, ESD protection, plus moisture
and corrosion resistance. All mating connectors will self-lock with one 360 degree turn of
the coupling nut.
Typical
MIL-STD-38999
Connectors
(shown with
tethered plugs)
Typical
MIL-STD-38999
Plug
(not typically
supplied with
switch)
Grounding
Use the provided 8-32 ground stud to connect the switch to a suitable safety, chassis or
earth ground. Use of heavy gauge (at least 16 AWG) grounding wire is recommended.
Make sure to follow your local or national codes for the proper ground connection.
Chassis
Ground
Connection
Point