Section 5
Pressure Vent
Pressure
Vent
Without a pressure ventilation system the pressure differential that can occur due to
temperature or altitude changes can result in condensation. To prevent this, the switch
incorporates a pressure vent that adjusts the internal air pressure to match the
surrounding (external) pressure. At the same time the vent is IP67 rated and will not let
moisture into the switch.
Characteristics of the Pressure vent
Air flow rate:
0,4 l/min at 0,1 bar ΔP to 5,0 l/min at 1 bar ΔP
Point of water entry:
1,5 bar
Temperature resistance:
–40°C to +120°C (in assembled state)