Protected Technology Policy - 

Red Lion protects your investment in Red Lion systems with 

long-term planned technology and our unique Protected Technology Policy. We will continue to support the 
specified capabilities of standard Red Lion products for at least five years (twenty years for Industrial 
Managed Switches). We plan each product improvement and new feature to be upward compatible with 
existing designs and installations. Our goals are to make each new software release bring new power to 
your Red Lion systems and have every existing feature, applications program and data file continue to work. 
We protect your investment even further with a liberal five-year trade-in policy. Exchange standard products 
for upgraded versions of the same product to take advantage of new features and improvements at any 
time for five years. A prorated trade-in allowance will be given for your existing unit. Red Lion protects your 
long-term productivity with state-of-the-art planned technology and continued support.

 

 

Red Lion Statement of Limited Warranty - 

Red Lion, manufacturer of Red Lion products, warrants to 

Buyer that products, except software, manufactured by Red Lion will be free from defects in material and 
workmanship. Red Lion's obligation under this warranty will be limited to repairing or replacing, at Red 
Lion's option, the defective parts within five (5) years of the date of installation, or within 60 months of the 
date of shipment from the point of manufacture, whichever is sooner. Products may be returned by Buyer 
only after permission has been obtained from Red Lion. Buyer will prepay all freight charges to return any 
products to the repair facility designated by Red Lion. This limited warranty does not cover losses or 
damages which occur in shipment to or from Buyer or due to improper installation, maintenance, misuse, 
neglect or any cause other than ordinary commercial or industrial applications. In particular, Red Lion 
makes no warranties whatsoever with respect to implied warranties of merchantability or fitness for any 
particular purpose. All such warranties are hereby expressly disclaimed. No oral or written information or 
advice given by Red Lion or Red Lion

’s representative shall create a warranty or in any way increase the 

scope of this warranty. This limited warranty is in lieu of all other warranties whether oral or written, 
expressed or implied. Red Lion's liability shall not exceed the price of the individual units, which are the 
basis of the claim. In no event shall Red Lion be liable for any loss of profits, loss of use of facilities or 
equipment, or other indirect, incidental or consequential damages.

 

 

INSTALLATION WARNINGS - 

These products should not be used to replace proper safety 

interlocking. No software-based device (or any other solid-state device) should ever be designed to 
be responsible for the maintenance of consequential equipment or personnel safety. In particular, 
Red Lion disclaims any responsibility for damages, either direct or consequential, that result from the 
use of this equipment in any application. All power, input and output (I/O) wiring must be in 
accordance with Class I, Division 2 wiring methods and in accordance with the authority having 
jurisdiction. Refer to section 1 for other important installation warnings.

 

 

FCC Statement 

This equipment has been tested and found to comply with the limits for a Class B digital 

device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generates, uses and can radiate 
radio frequency energy and, if not installed and used in accordance with the instructions, may cause 
harmful interference to radio communications. However, there is no guarantee that interference will not 
occur in a particular installation. If this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to 
correct the interference by one or more of the following measures: Reorient or relocate the receiving 
antenna; Increase the separation between the equipment and receiver; Connect the equipment into an 
outlet on a circuit different from that to which the receiver is connected; Consult the dealer or an 
experienced radio/TV technician for help.

 

 

Copyright & Trademarks - 

Copyright 

2014 Sixnet, Inc. All Rights Reserved.

 

 

 

 

Note:

 All information in this document is subject to change without notice. 

 

 

Summary of Contents for ET-8EG-MIL-1

Page 1: ... Manual Contents at a Glance Section 1 General Information Page 3 Section 2 Mechanical and Installation Page 6 Section 3 Power and Communication Wiring Page 7 Section 4 LEDs Page 12 Section 5 Pressure Vent Page 13 Section 6 Service and Contact Information Page 14 This manual applies to the following products ET 8EG MIL 1 IP67 unmanaged Ethernet switch with 8 Gigabit ports ET 8MG MIL 1 IP67 managed...

Page 2: ...All such warranties are hereby expressly disclaimed No oral or written information or advice given by Red Lion or Red Lion s representative shall create a warranty or in any way increase the scope of this warranty This limited warranty is in lieu of all other warranties whether oral or written expressed or implied Red Lion s liability shall not exceed the price of the individual units which are th...

Page 3: ...with real time systems The switch supports 10BaseT 10 Mbps 100BaseT 100 Mbps and 1000BaseT 1000 Mbps on 8 ports Each of these ports independently and automatically senses the speed and duplex for best performance They also offer auto crossover and auto polarity to assure a proper link with either straight or crossed wired cables or even when the cable is incorrectly wired Performance Specs The swi...

Page 4: ...11 x 6 x 2 85 279 x 152 x 72 mm Weight including caps 3 5 lbs 1 6 Kg IP67 dust oil and water tight package protection STANDARDS COMPLIANCE FCC part 15 ICES 003 EN55022 IEC61326 1 Safety UL508 CSA C22 2 No 142 and ISA12 12 01 CSA C22 2 No 213 MIL STD 461E for EMC performance MIL STD 810F for environmental performance MIL STD 1275B for power protection MANAGED MODELS USB RS232 console port via MIL S...

Page 5: ...ENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS Consignes de Sécurité 1 Le strict respect de ces avertissements contribuera à assurer la sécurité de l installation le démarrage et le fonctionnement de l interrupteur 2 INSTALLEZ L APPAREIL CONFORMÉMENT AUX CODES ÉLECTRIQUES LOCAUX ET NATIONAUX 3 DANGER DE FOUDRE NE PAS TRAVAILLER SUR L ÉQUIPEMENT PENDANT LES PÉRIODES ...

Page 6: ...ny flat surface The oval mounting holes or side slots will accept up to a 0 25 inch or 6 5 mm diameter screws 11 94cm 0 38 0 95cm 0 58 1 46cm Ø0 28 Ø0 70cm 0 25 0 64cm 5 75 14 61cm 6 00 15 24cm 0 51 1 30cm 5 49 13 94cm 0 35 0 89cm 1 50 3 81cm 2 85 7 24cm 2 24 5 69cm 2 45 6 22cm with plug 11 00 27 94cm 0 50 1 27cm RS232 USB managed only Power Input 0 26 0 67cm 1 83 4 66cm 4 36 11 09cm 6 61 16 80cm ...

Page 7: ...ng ESD protection plus moisture and corrosion resistance All mating connectors will self lock with one 360 degree turn of the coupling nut Typical MIL STD 38999 Connectors shown with tethered plugs Typical MIL STD 38999 Plug not typically supplied with switch Grounding Use the provided 8 32 ground stud to connect the switch to a suitable safety chassis or earth ground Use of heavy gauge at least 1...

Page 8: ...ions as shown in the diagram below Power Receptacle Location Power Receptacle Pinout Recommended Plug Model D38999 26WA98SA w socket contacts and A keying 10 Note The W in the above recommended plug specifies cadmium plating However you may choose a different plating to meet your requirements The MIL receptacles on the switch have black nickel plating which is RoHS compliant DC Supply C B A No Con...

Page 9: ...ow to access the switch via this console port Console Receptacle Location managed model only Console Receptacle Pinout Recommended Plug Model D38999 26WA35PA w pin contacts and A keying 11 Note The W in the above recommended plug specifies cadmium plating However you may choose a different plating to meet your requirements The MIL receptacles on the switch have black nickel plating which is RoHS c...

Page 10: ...t the speed and duplex of the connection Alternatively in the managed model the ports can be disabled or configured for fixed settings via one of the management interfaces See the software user manual for details Ethernet Receptacle Location typical Ethernet Receptacle Pinout Typical Pinout Connections Pin 1 TX For 10 100 Pin 2 TX For 10 100 Pin 3 RX For 10 100 Pin 4 TX For Gig Pin 5 TX For Gig Pi...

Page 11: ...A BI DA 2 green white green orange white orange TX TX TX D1 BI DA BI DA 3 white orange white green RX RX RX D2 BI DB BI DB 4 blue white blue blue white blue na na BI D3 na BI DC 5 white blue white blue na na BI D3 na BI DC 6 orange white orange green white green RX RX RX D2 BI DB BI DB 7 white brown white brown na na BI D4 na BI DD 8 brown white brown brown white brown na na BI D4 na BI DD BI BI d...

Page 12: ... flash when loading firmware and briefly on power up or reset Otherwise if it is OFF or flashing for an extended period of time then a problem is detected In this case please contact technical support Power LEDs There is a power LED labeled as Power It will be on solid when power is applied to the switch Ethernet LEDs The switch has a set of LEDs to indicate the status of various operating conditi...

Page 13: ...o temperature or altitude changes can result in condensation To prevent this the switch incorporates a pressure vent that adjusts the internal air pressure to match the surrounding external pressure At the same time the vent is IP67 rated and will not let moisture into the switch Characteristics of the Pressure vent Air flow rate 0 4 l min at 0 1 bar ΔP to 5 0 l min at 1 bar ΔP Point of water entr...

Page 14: ...lled if the repair is covered under warranty Please supply us with as many details about the problem as you can The information you supply will be written on the RO form and supplied to the repair department before your unit arrives This helps us to provide you with the best service in the fastest manner Repairs are completed as soon as possible If you need a quicker turnaround ship the unit to us...