PROGRAMMING

The CUB7P has programmable prescale values and decimal point positions.

These values are changed using the front panel push buttons. Connect wires
between RST EN (Reset Enable) and COM. (Common); and between HS
(Program Enable) and COM. (Common) to enable front panel push buttons.

Note: Upon entering the PGM mode for the first time, the Prescaler value is

set to 0.0000. Some value between 0.0001 and 1.9999 must be entered in
order for the CUB7P to operate properly. Previously stored values are
retained until changed by the user.

With the front panel push buttons enabled, press the PGM button to enter the

program mode. The CUB7P display will change to the current prescale value,
with the least significant digit flashing at a 2 Hz rate. The prescale value can be
set to any value between 0.0001 and 1.9999. Press the RST button to increment
the flashing digit to the desired value. Pressing the PGM button will lock in the
value of the flashing digit and advance to the next significant digit. The most
significant digit can only be set to 0 or 1. When the entire prescale value has
been programmed, press the PGM button once to enable decimal point
selection. Any new count pulses will be accumulated using the new prescale
value. 

After performing the prescale selection, the display will show 0.0000.

Decimal point positions can be set for:

Press the RST button until the desired decimal point position is displayed.

Press the PGM button to select that position and return to the counter mode.
Remove the wire from the HS (Program Enable) terminal to prevent accidental
changes to the programmed values.

Note: The incrementing edge of the count signal will change when the PGM

button is pressed for the first time. To avoid incorrect display information, it is
recommended that the CUB7P be reset after making programming changes.

COUNT EDGE

Accessing program mode for the first time will complement the

incrementing edge of the count signal. The table below shows the incrementing
edge of the count signal for the different versions of the CUB7P.

2

SPECIFICATIONS

1. 

DISPLAY

: 8-digit LCD, 0.35" (8.90 mm) high digits.

2. 

POWER SOURCE

: Replaceable Internal 3.0 V lithium battery to provide up

to 6 years of continuous operation. (Battery life is dependent upon usage.
Contacts that remain closed for long periods of time reduce battery life.)

3. 

BACKLIGHT POWER REQUIREMENTS: 

9 to 28 VDC; 35 mA. typical,

50 mA max. Above 26 VDC, derate max. operating temperature to 40°C.
Must use NEC Class 2 or SELV rated power supply.

4. 

SIGNAL INPUT

: (LS terminal #4) See 

Count Edge

under Programming for

incrementing edge of input signal.

Contact Input

(CUB7P0xx): 30 Hz max. from Switch Contact or solid state

Transistor Switch to Common with a50% duty cycle. Contact burden 7 µA max.

Logic Input

(CUB7P2xx): 10 KHz max. from a 3.0V bipolar output or 200

Hz max.from a solid state Transistor Switch to Common with a 50% duty
cycle. Contact burden 7 µA max.

5. 

REMOTE RESET

: 15 msec min. pulse width (active low) from 3.0 V

bipolar output, an open collector transistor, or a switch contact to common.

6. 

ENVIRONMENTAL CONDITIONS

:

Operating Temperature Range

: 0 to 50°C Derate max. operating

temperature to 40°C above 26 VDC (Backlight versions).

Storage Temperature

: -30 to 80°C

Operating and Storage Humidity

: 85% max. relative humidity (non-

condensing) from 0°C to 50°C.

Vibration According to IEC 68-2-6:

5 to 500 Hz, in X, Y, Z direction for 1.5

hours, 5g’s.

Shock According to IEC 68-2-27:

Operational 30 g, 11 msec in 3 directions.

Altitude

: Up to 2000 meters

7. 

CERTIFICATIONS AND COMPLIANCES

SAFETY

UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95

LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards

Type 4X Indoor Enclosure rating (Face only), UL50

IEC-61010-1, EN 61010-1: Safety requirements for electrical equipment

for measurement, control, and laboratory use, Part 1.

IP65 Enclosure rating (Face only), IEC 529

ELECTROMAGNETIC COMPATIBILITY

Notes

1. Backlit powered units require a power line filter to be installed, RLC

LFIL0000 or equivalent, so as not to impair the function of the
backlighting.

Refer to EMC Installation Guidelines for additional information.

8. 

CONNECTIONS

: Wire clamping screw terminals

Wire Strip Length

: 0.3" (7.5 mm)

Wire Gage

: 30-14 AWG copper wire

Torque

: 5 inch-lbs (0.565 N-m) max.

9. 

CONSTRUCTION

: High impact plastic case with clear viewing window.

The front panel meets NEMA 4X/IP65 requirements for indoor use when
properly installed. Installation Category I, Pollution Degree 2. Panel gasket
and mounting clip included.

10. 

WEIGHT

: 2 oz. (57 grams) [with battery]

900 MHz 

± 5 MHz

Immunity to EN 50082-2

200 Hz, 50% duty cycle

Electrostatic discharge

EN 61000-4-2

Level 2; 4 Kv contact 
Level 3; 8 Kv air

Electromagnetic RF fields

EN 61000-4-3

Level 3; 10 V/m 
80 MHz - 1 GHz

Fast transients (burst)

EN 61000-4-4

Level 4; 2 Kv I/O
Level 3; 2 Kv power 

1

RF conducted interference

EN 61000-4-6

Level 3; 10 V/rms 
150 KHz - 80 MHz

Simulation of cordless telephone

ENV 50204

Level 3; 10 V/m

Emissions to EN 50081-1

RF interference

EN 55022

Enclosure class B

VERSION

AFTER INSTALLING OR

REPLACING BATTERY

AFTER ENTERING

PROGRAM MODE

CUB7P0 (Contact)

Rising Edge

Falling Edge

CUB7P2 (Logic)

Rising Edge

Falling Edge

0.0000 (Default)

0

0.00000

0.0

0.000000

0.00

00000000

0.000

Summary of Contents for CUB7P

Page 1: ...s that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not...

Page 2: ...erature to 40 C Must use NEC Class 2 or SELV rated power supply 4 SIGNAL INPUT LS terminal 4 See Count Edge under Programming for incrementing edge of input signal Contact Input CUB7P0xx 30 Hz max fro...

Page 3: ...uch as ferrite suppression cores is effective Install them on Signal and Control cables as close to the unit as possible Loop the cable through the core several times or use multiple cores on each cab...

Page 4: ...when properly installed The units are intended to be mounted into an enclosed panel The viewing window and reset button are factory sealed for a washdown environment A sponge rubber gasket and mounti...

Page 5: ...max voltage drop 0 5 V when ON The OFF state leakage current must be less than 2 A Note The RC protection circuit on the RST Input causes a delay of approximately 15 msec in Reset response L S INPUT C...

Page 6: ...t versions of the CUB7P require an external 9 to 26 VDC power supply The external supply is connected between the V and common terminals as shown in the drawing APPLICATION TOTAL YARDS OF MATERIAL A f...

Page 7: ...For Sales and Support Contact Walker EMD Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com 7 This page intentionally left blank...

Page 8: ...or products containing components manufactured by RLC and based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be...

Reviews: