red lion CUB5RT Manual Download Page 5

5

4.1  POWER WIRING

COMM

USR

+9-28 VDC

EXC

INP+

PWR COMMON

+

-

DC Power

+9 to +28 VDC: +VDC
Power Common: -VDC

4.2  USER INPUT WIRING

COMM

USR

+9-28 VDC

EXC

INP+

PWR COMMON

Sinking Logic 

USR COMM
USR

The user input of the meter is 
internally pulled up to +9 to +28 V 
with 10 K resistance. The input is 
active when it is pulled low (<0 .7 V).

Connect external switching device between the 
User Input terminal and User Input Common.

}

4.3  INPUT WIRING

4.4  SETPOINT (OUTPUT) WIRING

4.5  SERIAL COMMUNICATION WIRING

COM

N.C.

N.O.

SINGLE SETPOINT RELAY PLUG-IN CARD

N/C

RS485

2

COMM

A+

B-

N/C

5

3

4

N/C

RS232

5

N/C

TX

N/C

4

3

COMM

COMM

2

RX

6

1

6

1

COM

N.O.

N.C.

ELECTRICAL CONNECTIONS

DUAL SETPOINT N-FET OPEN DRAIN PLUG-IN CARD

COM

OSNK 1(2)

(30 V MAX.)

ELECTRICAL CONNECTIONS

OSNK1

OSNK2

COM

3-WIRE RTD

COMM

INP+

EXC

2-WIRE RTD

COMM

INP+

EXC

JUMPER

CAUTION: Power input common and sensor input common are NOT isolated 

from user input common. In order to preserve the safety of the meter 
application, the power input common and the sensor input common must 
be suitably isolated from hazardous live earth referenced voltages; or 

input common must be at protective earth ground potential. If not, hazardous 
live voltage may be present at the User Inputs and User Input Common 
terminals. Appropriate considerations must then be given to the potential of 
the user input common with respect to earth common; and the common of 
the isolated plug-in cards with respect to input common.

Output Common is not isolated from DC Power Common. Load 

must be wired between OSNK terminal and V+ of the load supply.

4.6  USB PROGRAMMING

USB PROGRAMING PLUG-IN CARD

SERIAL COMMUNICATIONS PLUG-IN CARD

RJ11 CONNECTOR PIN OUTS

Summary of Contents for CUB5RT

Page 1: ...this literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not specified by...

Page 2: ...es for additional information 8 MEMORY Nonvolatile E2PROM memory retains all programming parameters and max min values when power is removed 9 CONNECTIONS Wire clamping screw terminals Wire Strip Leng...

Page 3: ...Insert the unit into the panel cutout While holding the unit in place push the panel latch over the rear of the unit so that the tabs of the panel latch engage in the slots on the case The panel latch...

Page 4: ...MI suppression devices or equivalent are recommended Fair Rite part number 0443167251 RLC part number FCOR0000 Line Filters for input power cables Schaffner FN2010 1 07 Red Lion Controls LFIL0000 6 To...

Page 5: ...NNECTIONS OSNK1 OSNK2 COM 3 WIRE RTD COMM INP EXC 2 WIRE RTD COMM INP EXC JUMPER CAUTION Power input common and sensor input common are NOT isolated from user input common In order to preserve the saf...

Page 6: ...ges to memory and return the meter to the Display Mode If power loss occurs before returning to the Display Mode verify recent parameter changes PROGRAMMING TIPS It is recommended to start with Module...

Page 7: ...be automatically loaded for the selected type The position of the Input Range Jumper must match the RTD type selected F SCALE TEMPERATURE SCALE Select the temperature scale This selection applies for...

Page 8: ...ess the SEL button Display reads 00r 5 Apply a direct short to terminals INP EXC and COMM using a three wire link Press SEL Display reads CALC for about 15 seconds 6 When the display reads 15 0r apply...

Page 9: ...rogramming Immediate Access Entering Code 222 allows access regardless of security code 6 3 MODULE 3 DISPLAY AND FRONT PANEL BUTTON PARAMETERS 3 dSP SEL Pro Front Panel Display Select Enable Display U...

Page 10: ...Balanced Hys LO bL OUTPUT STATE OFF ON Hys SP SP Hys OFF TRIGGER POINTS High Acting Unbalanced Hys HI Ub 2 HYS n HYSTERESIS VALUE 1 to 59999 Enter desired hysteresis value See Setpoint Output Figures...

Page 11: ...ns Meter Address Abbreviated Printing 5 SEr bAUd dAtA PAr Addr Abbr OPt Pro The Serial Setup Parameters are only active when one of the optional serial communications programming cards is installed in...

Page 12: ...it Only Programming Security Code CodE Display Decimal Point RTD Type tYPE 1 INP Temperature Scale SCALE dECPt USrIN User Input Function Filter Setting Display Offset Value OFSEt FILtr Filter Band bAN...

Reviews: