red lion CUB5RT Manual Download Page 12

Setpoint  

Action

Setpoint 

Select

Setpoint 

Value

Output Reset 

Action

Hysteresis 

Value

Off Time 

Delay

On Time 

Delay

Output Reset 

With Display 

Reset

Change Display 

Color with 

Output State

Backlight 

Unit Only

SPSEL

4-SPt

Act-n

SPt-n

HYS-n

tON-n

tOF-n

rSt-n

rEn-n

ChC-n

Standby 

Operation

Stb-n

brn-n

Probe 

Burn-out

Action

Front Panel 

Reset Enable

Front Panel 

Display 

Select Enable

Display 

Update Time

dSP-t

SEL

rSt

3-dSP

Display 

Intensity 

Level

COLOr

Display 

Scroll 

Enable

ScroL

Display 

Color

d-LEV

Backlight Unit Only

Programming 

Security Code

CodE

Display 

Decimal Point

RTD Type

tYPE

1-INP

Temperature 

Scale

SCALE

dECPt

USrIN

User Input 

Function

Filter Setting

Display Offset 

Value

OFSEt

FILtr

Filter Band

bANd

U-ASN

User Input 

Assignment

LLOO-

-EEn

n

Min Display 

Enable

Max Capture 

Delay Time

Max Display 

Enable

HI-En

HI-t

2-SEC

Min Capture 

Delay TIme

LLOO-

-tt

Factory 

Service 

Operations

FCS

Access Code 

For Service 

Operations

CodE

PAr

Parity Bit

Baud Rate

bAUd

Data Bit

dAtA

5-SEr

Meter 

Address

Addr

Abbreviated 

Printing

Abbr

Print 

Options

OPt

SEL

RST

NO

  

Pro

Exit 

Programming

End

SEL

RST

RST

RST

RST

RST

SEL

SEL

SEL

SEL

CUB5RT PROGRAMMING QUICK OVERVIEW

Press and hold 

SEL

 button 

to enter Programming 

Mode.

Summary of Contents for CUB5RT

Page 1: ...this literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not specified by...

Page 2: ...es for additional information 8 MEMORY Nonvolatile E2PROM memory retains all programming parameters and max min values when power is removed 9 CONNECTIONS Wire clamping screw terminals Wire Strip Leng...

Page 3: ...Insert the unit into the panel cutout While holding the unit in place push the panel latch over the rear of the unit so that the tabs of the panel latch engage in the slots on the case The panel latch...

Page 4: ...MI suppression devices or equivalent are recommended Fair Rite part number 0443167251 RLC part number FCOR0000 Line Filters for input power cables Schaffner FN2010 1 07 Red Lion Controls LFIL0000 6 To...

Page 5: ...NNECTIONS OSNK1 OSNK2 COM 3 WIRE RTD COMM INP EXC 2 WIRE RTD COMM INP EXC JUMPER CAUTION Power input common and sensor input common are NOT isolated from user input common In order to preserve the saf...

Page 6: ...ges to memory and return the meter to the Display Mode If power loss occurs before returning to the Display Mode verify recent parameter changes PROGRAMMING TIPS It is recommended to start with Module...

Page 7: ...be automatically loaded for the selected type The position of the Input Range Jumper must match the RTD type selected F SCALE TEMPERATURE SCALE Select the temperature scale This selection applies for...

Page 8: ...ess the SEL button Display reads 00r 5 Apply a direct short to terminals INP EXC and COMM using a three wire link Press SEL Display reads CALC for about 15 seconds 6 When the display reads 15 0r apply...

Page 9: ...rogramming Immediate Access Entering Code 222 allows access regardless of security code 6 3 MODULE 3 DISPLAY AND FRONT PANEL BUTTON PARAMETERS 3 dSP SEL Pro Front Panel Display Select Enable Display U...

Page 10: ...Balanced Hys LO bL OUTPUT STATE OFF ON Hys SP SP Hys OFF TRIGGER POINTS High Acting Unbalanced Hys HI Ub 2 HYS n HYSTERESIS VALUE 1 to 59999 Enter desired hysteresis value See Setpoint Output Figures...

Page 11: ...ns Meter Address Abbreviated Printing 5 SEr bAUd dAtA PAr Addr Abbr OPt Pro The Serial Setup Parameters are only active when one of the optional serial communications programming cards is installed in...

Page 12: ...it Only Programming Security Code CodE Display Decimal Point RTD Type tYPE 1 INP Temperature Scale SCALE dECPt USrIN User Input Function Filter Setting Display Offset Value OFSEt FILtr Filter Band bAN...

Reviews: