6.4  MODULE 4 - S

ETPOINT

 O

UTPUT

 P

ARAMETERS

 (

4-SEtPt

)

SEL

Setpoint 2 

Enable

Setpoint 

Select

Setpoint 

Assignment

Setpoint 

Output Logic

Setpoint 

Output 

Action

Setpoint 

Value

Setpoint 

Output 

Time-out

SP2 Only

Setpoint 

Annunciator

SPt 

 SEL

4-SEtPt

SP2 

 Enb

SPn 

 ASN

SPn 

 ACt

SPn tOUt

SPn 

 VAL

SPn 

 OUt

SPn 

 LIt

PPrroo

SPn P-UP

SPn StbY

Setpoint 
Standby 

Operation

Setpoint 

Boundary 

Type

SPn tYPE

Counter 

Auto Reset

SPn AUtO

SPn 

 ChC

Change Display 

Color with 

Output State

SP2 Output 

Off at SP1 

Output

SP1 Output 

Off at SP2 

Output

SP1 OFF2

SP2 OFF1

Setpoint 

Output Reset 

with Manual 

Reset

SPn 

 rSt

Setpoint Output 

Power-up 

State

SP1 Only

SP2 Only

Backlight 

Unit Only

PARAMETER MENU

The Setpoint Output Parameters are only active when an optional Setpoint 

Output Module is installed in the meter. Some parameters in the menu will not 
appear depending on the Setpoint Assignment and Setpoint Output Action. The 
Setpoint Parameter Availability chart below illustrates this. 

PARAMETER

DESCRIPTION

BOUNDARY

bOUNd

LATCH

LAtCH

RATE ASSIGNMENT

TIMED OUT

t-OUt

BOUNDARY

bOUNd

LATCH

LAtCH

Yes

No

No

Yes

No

No

SPn VAL

Setpoint Value

Yes

Yes

Yes

Yes

Yes

Yes

SPn OUt

Setpoint Output Logic

Yes

Yes

Yes

Yes

Yes

Yes

SPn LIt

Setpoint Annunciator

Yes

Yes

Yes

Yes

Yes

Yes

SPn P-UP

Setpoint Output Power-up State

No

No

Yes

No

No

Yes

SPn tYPE

Setpoint Boundary Type

No

Yes

No

Yes

Yes

Yes

SPn StbY

Standby Operation (Low acting only)

No

Yes

No

Yes

Yes

Yes

SPn AUtO

Counter Auto Reset

Yes

No

Yes

No

No

No

SP1 OFF2

SP1 Output Off at SP2 (SP1 only)

Yes

No

Yes

No

No

No

SP2 OFF1

SP2 Output Off at SP1 (SP2 only)

Yes

No

Yes

No

No

No

SPn rSt

Output Reset with Manual Reset

Yes

No

Yes

Yes

No

Yes

SPn ChC

Change Display Color w/ Output State

Yes

Yes

Yes

Yes

Yes

Yes

Setpoint Output Time-out Value

TIMED OUT

t-OUt

COUNTER ASSIGNMENT (A or B) *

SPn tOUt

* BOUNDARY Setpoint Action not applicable for Counter B Assignment

Select the Setpoint Output to be programmed, starting with Setpoint 1. The 

"

n

" in the following parameters reflects the chosen Setpoint number. After 

 

Setpoint 1 is completely programmed, the display returns to 

SPt SEL

. Repeat 

steps for Setpoint 2 if both Setpoints are used in the application.

Select 

NO

 to exit the Setpoint programming module. The number of Setpoints 

available is dependent on the Setpoint option module installed.

SETPOINT SELECT

SP2

SP1

NO

NO

SPt SEL

SETPOINT 2 ENABLE (SP2 Only)

Select 

YES

 to enable Setpoint 2 and access the setup parameters. If 

NO

 is 

selected, the unit returns to 

SPt SEL

 and Setpoint 2 is disabled.

YES

NO

NO

SP2 Enb

SETPOINT ASSIGNMENT

SETPOINT PARAMETER AVAILABILITY

Select the display to which the Setpoint is assigned.

Count A

SPn ASN

SETPOINT OUTPUT ACTION

The parameter selects the action of the Setpoint Output as described in the 

chart. Boundary output action is not applicable for Counter B assignment.

LAtCH

SPn ACt

Count A

Count b

rAtE

LAtCH

t-OUt

bOUNd

SPT ACTION DESCRIPTION

OUTPUT ACTIVATES

OUTPUT DEACTIVATES

LAtCH

Latched Output Mode

When Count = 

Setpoint

At Manual Reset 

(if 

SPn rSt

=

YES

)

t-OUt

Timed Output Mode

When Count = 

Setpoint

After Setpoint 

Output Time-Out

bOUNd

Boundary Mode 
(Low Acting Type)

Boundary Mode 
(High Acting Type)

When Count 



Setpoint

When Count 



Setpoint

When Count 

 Setpoint

When Count 

< Setpoint

Summary of Contents for CUB5 Series

Page 1: ...d installable with the addition of the single setpoint relay output card or the dual setpoint solid state output card Serial communications capability for RS232 or RS485 is added with a serial option...

Page 2: ...re Range for CUB5R000 35 to 75 C Operating Temperature Range for CUB5B000 depends on display color and intensity level as per below INTENSITY LEVEL TEMPERATURE Red Display 1 2 35 to 75 C 3 35 to 70 C...

Page 3: ...ensor User Input Commons 1400 Vrms for 1 min Working Voltage 150 Vrms Contact Rating 1 amp 30 VDC resistive 0 3 amp 125 VAC resistive Life Expectancy 100 000 minimum operations Response Time Turn On T...

Page 4: ...adios are used in close proximity or if the installation is near a commercial radio transmitter 4 Signal or Control cables within an enclosure should be routed as far as possible from contactors contr...

Page 5: ...PWR COMMON 1 ON 2 3 9 28 VDC PWR COMMON 1 ON 4 2 3 INP B INP COMM USR INP A PWR COMMON 1 2 4 3 ON INP COMM USR 9 28 VDC INP B INP A AC Inputs From Tach Generators Etc Input A Two Wire Proximity Curre...

Page 6: ...key with Pro NO displayed This will commit any stored parameter changes to memory and return the meter to the Display Mode If power loss occurs before returning to the Display Mode verify recent param...

Page 7: ...oint s The count source for the batch counter can be SP1 SP2 or both Batch counting is available in all count modes except Dual Counter which uses an external input signal for Counter B This parameter...

Page 8: ...eset Setpoint 1 and 2 outputs Reset Setpoint 2 output Reset Setpoint 1 output Same as Print Request followed by a momentary reset of the selected counter s Change backlight color with each activation...

Page 9: ...a pulse every 2 seconds RATE HIGH UPDATE TIME 0 2 to 99 9 seconds 01 0 LO Udt 02 0 HI Udt SCALING FOR RATE INDICATION To scale the rate enter a Scaling Display value with a corresponding Scaling Input...

Page 10: ...unter s The shaded selections are only active when Counter B is enabled Dual Count mode or batch counter FRONT PANEL COUNTER RESET ENABLE RST The yES selection allows the display to automatically scro...

Page 11: ...Yes No Yes No No No SP2 OFF1 SP2 Output Off at SP1 SP2 only Yes No Yes No No No SPn rSt Output Reset with Manual Reset Yes No Yes Yes No Yes SPn ChC Change Display Color w Output State Yes Yes Yes Yes...

Page 12: ...vated Reverse rEV turns the output off when activated and on when deactivated NOr SPn OUt SETPOINT ANNUNCIATOR Normal NOr displays the setpoint annunciator when the corresponding output is on Reverse...

Page 13: ...parameter can be sent to a printer or computer as a block Selecting YES displays a sublist for choosing the meter parameters to appear in the print block All active parameters entered as YES in the s...

Page 14: ...change commands follow with a transmit value command for readback verification Receiving Data From The Meter Data is transmitted from the meter in response to either a transmit command T a block print...

Page 15: ...RXD 3 to 15 V a b 200 mV Voltage levels at the Receiver Data is transmitted one byte at a time with a variable idle period between characters 0 to Each ASCII character is framed with a beginning start...

Page 16: ...ype Setpoint Standby Operation SPn tYPE SPn StbY SPt SEL Setpoint Select Setpoint 2 Enable SP2 Enb Setpoint Output Action Setpoint Assignment SPn ASN SPn ACt Setpoint Output Reset with Manual Reset SP...

Reviews: