45
20-CLEANING AND MAINTENANCE
Technical Dept. - All rights reserved - Reproduction prohibited
CHECKING THE INTERNAL COMPONENTS
ATTENTION!
The internal electromechanical components must only be checked by qualified personnel whose technical expertise
includes combustion and electricity.
We recommend that an annual maintenance service is carried out (with a scheduled service contract). This service is essentially a visual
and functional inspection of the internal components. The following is a summary of the checks and/or maintenance that are essential for
the correct operation of the product.
Cleaning under the user’s responsibility
PARTS/INTERVAL
15 DAYS
30 DAYS
60 DAYS
Brazier
·
Trolley
·*
·*
Lower compartment
·*
·*
*SEE PARAGRAPH “CLEANING THE TROLLEY”
Cleaning performed by the qualified Technician
PARTS/INTERVAL
7 DAYS
15 DAYS
60 DAYS
1 YEAR
Complete exchanger
·
Smoke duct
·
Door gasket
·
Internal parts
·
Flue
·
Circulation pump
·
Plate heat exchanger
·
Plumbing components
·
Electro-mechanical components
·
Overpressure silicon damper for combustion chamber
·
CLEANING THE CONTROL PANEL DISPLAY
ATTENTION!!
THE PANEL DISPLAY IS VERY DELICATE, IT IS SUPPLIED WITH A PROTECTIVE FILM.
RECOMMENDATIONS FOR CLEANING:
Clean using a soft cotton cloth, which should be dry or slightly moist.
Do not use aggressive detergents or polyester materials.
Do not use abrasive sponges or powder detergents nor solvents such as alcohol and petrol, since they may damage the surface of the
device.