16-SETTINGS MENU

CLEANING CYCLE

This function can only be activated with the boiler in OFF supply:

from the Settings menu- press ok (E key), press the D key (arrow key), scroll up to the “ciclo pulizia” (cleaning cycle) press OK (E key)- 

Activate/deactivate cleaning.

This procedure activates the fumes extraction fan at the maximum level in order to clean the brazier and expel soot.

This function also activates: mechanical cleaning of the brazier, turbolators and compactor.

LANGUAGE

This function is used to choose the desired language among those set in the control panel.

To enter the function, from the Settings menu - press ok (E key), press the D key (arrow key) and scroll up to language item, press OK (E 

key) and choose the language among the various ones set and finally press Ok (“E” key) to confirm.

The available languages are: Italian/English/French/German/Spanish/Dutch/Danish

TIME-DATE

This function is used to set date and time.

To enter the function, from the Settings menu - press ok (E key), press the D key (arrow key) and scroll up to the date-time item, press OK 

(E key) to enter the function. Next, press the “E” (ok) key again to modify day/month/year/hour and minutes. To modify the parameters, 

use the “C” and “D” (arrow keys) keys and press the “E” key to confirm.

B

E

INFO

OK

C

B

EXIT

IMMEDIATELY ACTIVATE A CLEANING

CYCLE OF THE BRAZIER

SETTINGS-CLEANING

DEACTIVATE

CLEANING

ACTIVATE

CLEANING

B

E

OK

C

D

SETTINGS-LANGUAGE

ITALIANO

ENGLISH

FRANCAIS

B

E

OK

C

D

SETTINGS-TIME-DATE

TODAY IS MONDAY 

AND IT IS 

24/06/13

14:14

EXIT

Summary of Contents for PERFORMA 25 EasyClean Plus

Page 1: ...INSTALLATION GUIDE GB Instructions in English PELLET BOILER PERFORMA 25 EasyClean Plus PERFORMA 30 EasyClean Plus PART 2 OPERATION AND CLEANING...

Page 2: ...ART UP 4 14 MENU STRUCTURE 8 15 INFORMATION MENU 11 16 SETTINGS MENU 14 17 TECHNICAL MENU 31 18 SAFETY DEVICES AND ALARMS 32 19 RECOMMENDATIONS FOR SAFE USE 38 20 CLEANING AND MAINTENANCE 39 20 CLEANI...

Page 3: ...the boiler as well as the identification code of any malfunction B Function selection key indicated by the upper display i e start up shutdown C Function selection key indicated by the upper display i...

Page 4: ...e OFF otherwise one enters the following parameter SELECT LANGUAGE At initial start up if it has never been set the LANGUAGE choice screen appears The system displays all possible languages Using the...

Page 5: ...keys B and E respectivelycorrespondingtoONandMENU willmakeitpossibletoaccessthepanelorthemenu Ifnokeyispressed thedisplay will once again show OFF after 5 seconds SCREEN ON ACTIVATED COMPACTOR ACTIVA...

Page 6: ...evel bars one bar corresponds to minimum power 5 bars to maximum power this level is determined by the heating system heat requirements the boiler adjusts pellet loading parameters fumes extraction an...

Page 7: ...gured see the menu settings input aux Select what is to be set and then using the C and D keys increase decrease the temperature use the E key to confirm while the B key is used to exit and return to...

Page 8: ...ose the programme to be set Programme selection makes it possible to choose between one of the following options one choice excludes the other TIMER 1 TIMERWITH REFERENCETOTHE AMBIENTTEMPERATURE TIMER...

Page 9: ...display Once temperature programming for Monday is complete press the B SALVA SAVE key If the same temperature scale of Monday is desired for other weekdays after saving E key press the C key COPIA C...

Page 10: ...WATER With the centre arrow keys C and D it is possible to increase decrease the temperature value while the B key is used to move to the next temperature With the E key OK the set values are confirme...

Page 11: ...vailable information is Software Data memory All memory Boiler state SOFTWARE INFORMATION The available data in this function are CODE FIRMWARE DATABASE INTERFACE It is information that can be used to...

Page 12: ...ONS TEST DATE ALARM MEMORY INFORMATION It gives information about the last alarms detected EXIT INFORMATION DATA HYSTORY WORKING HOURS 100 TOTAL IGNITIONS 20 TEST DATE 15 01 2013 EXIT INFORMATION ALAR...

Page 13: ...4 95 cleaning state WATERTEMP Water temperature detected by the probe inside the boiler and related SET AUX PROBE detects the value measured by the aux sensor external storage cylinder puffer ACTIVE V...

Page 14: ...he chosen function SETTINGS Auto Eco default activated Feed screw loading Pellet recipe Active Cleaning cycle Language date time Aux Input aux output Room Input T on Pump Pump pwm Antifreeze function...

Page 15: ...quest heating sanitary puffer AUTO ECO DEACTIVATED With the boiler on if Auto eco is deactivated and there are no heat requests different based on menu settings aux input settings the boiler operates...

Page 16: ...s ok E key press the D key arrow key and scroll up to load feed screw press OK E key and activate deactivate the function press ok E key to confirm MAXIMUM POWER This feature allows you to set the max...

Page 17: ...nt from any type of connection to the flue which with traditional systems may constitute a problem during the installation phase Thanks to an internal sensor the boiler is extremely reliable and preci...

Page 18: ...and scroll up to language item press OK E key and choose the language among the various ones set and finally press Ok E key to confirm The available languages are Italian English French German Spanish...

Page 19: ...tat choice implies the pump aux output designation RoomTherm 2 The boiler heat request may take place from any part of the room probe or from the Termostato Amb 2 Room thermostat 2 installed in a room...

Page 20: ...ve must be connected to contacts 10 11 12 Storage cylinder thermostat To activate this option connect a Normally Open N O contact thermostat to points 1 and 2 of the back 9 pole terminal board The hea...

Page 21: ...is only to control the heating system pump controlled by the potential free contact on terminals 7 8 9 if the system pump is activated in Aux out mode POS 1 2 AUX INPUT EXTERNALTHERMOSTAT THERMOSTAT...

Page 22: ...ations in force Installation and verification of operation is to be performed only by specialised authorised personnel The manufacturerwillnotbeheldliablefornon compliancewiththeprovisionslistedabove...

Page 23: ...ttable SET VALUES WATERTEMP 60 C 80 C BOILERTEMP 10 C 70 C Parameters to be set Settings Value AMB Input Room thermostat AUX Input Boiler Probe AUX Output None Hydraulic diagram Num Description Num De...

Page 24: ...ettable SET VALUES STORAGETEMP 50 C 80 C Parameters to be set Settings Value AMB Input RoomThermostat AUX Input Puffer Probe AUX Output Puffer Pump Hydraulic diagram Num Description Num Description 1...

Page 25: ...settable SET VALUES STORAGETEMP 50 C 80 C Parameters to be set Settings Value AMB Input None AUX Input Puffer Probe AUX Output Auxiliary boiler Hydraulic diagram Num Description Num Description 1 Pell...

Page 26: ...TEMP 50 C 80 C BOILERTEMP 10 C 70 C Parameters to be set Settings Value AMB Input Puffer Probe AUX Input Boiler Probe AUX Output None Hydraulic diagram Num Description Num Description 1 Pellet Boiler...

Page 27: ...D keys to select the Remote Alarm Aux boiler Output in temp and press OK E key If the Aux output is set on Remote Alarm the NO contact is closed when an alarm is present If the Aux output is set to A...

Page 28: ...Input pressOK Ekey andselectroomthermostat press E key to confirm Attention If room temperature is selected weekly hourly Programming is not available PUMP ONT This function enables adjustment of the...

Page 29: ...i freeze activation conditions PUMP ON are boiler temp anti freeze set 3 C The level 2 anti freeze activation conditions PUMP and FLAME ON are boiler temp anti freeze set Anti freeze activation condit...

Page 30: ...ast and brightness This function is found in fromtheSettingsmenu pressok Ekey presstheC Dkey arrow andscrolluptoDisplay pressOK Ekey Modifythesettingsusingthe B C D keys and press the E key to confirm...

Page 31: ...elect Technical menu and press OK E key Enter the password and press the E key to confirm To enter the password using the C and D keys set the numbers 1 2 3 9 with the E OK key confirm and move on to...

Page 32: ...he boiler is protected against violent changes in current by a general fuse located in the control panel at the back of the boiler Other fuses that protect the circuit boards are located on the latter...

Page 33: ...rules contained in the manual and in particular All the necessary measures and or precautions must be adopted when performing maintenance cleaning and repairs Donottamperwiththesafetydevices Donotrem...

Page 34: ...urned material Make sure the spark plug warms up Thoroughly empty and clean the brazier before restarting A02 NO FLAME The fire goes out abnormally without acoustic alarm Check the level of pellets in...

Page 35: ...S MENU Pellet recipe If the alarm persists contact the service centre A14 ACTIVE SENSOR Active sensor anomaly Active Plus sensor operation anomaly Contact an authorised service centre to have the comp...

Page 36: ...conditions NEVER open the boiler door whilst it is either in the initial start up or on its shut down cycle pellets will still be smolderingorthereforevolatilesmaybepresent ATTENTION If during operat...

Page 37: ...nel displays the wording OFF see screen but if it is in shut down due to an alarm condition the small panel displays the related code See alarms table BLACKOUTWITH BOILER ON If power is lost for less...

Page 38: ...that the product is installed in compliance with standards in force Furthermore it is of the utmost importance to respect the following simple rules Every time the brazier is removed for cleaning it...

Page 39: ...adjusting the checks to the kind of fuel you are using Red recommends using A1 class pellets with an ash residue of less than 0 7 REMEMBER THAT ONLY A BRAZIER THAT IS CLEANED CORRECTLY CAN GUARANTEE S...

Page 40: ...s closethetwocaps 6 nearthefeedscrewinsertionhole toavoidloosingashduringtransport Thefrontorrearcapsdependingon whether the trolley is located to the right or left of the boiler open the trolley cove...

Page 41: ...trolley emptying and cleaning of lower augers with vacuum cleaner During automatic cleaning the boiler activates The pipe scraper linkage thus cleaning the heat exchanger keeping it always efficient...

Page 42: ...EDTECHNICIAN CLEANINGTHE SMOKE EXTRACTOR COMPARTMENT This operation must be performed by a technician authorised once per season To do this cleaning it is necessary to disassemble the lower augers thi...

Page 43: ...semble the cladding to be able to assess the anomalous protrusion of the block when the door is closed SHUTDOWN end of season At the end of each season before switching the product off it is recommend...

Page 44: ...side panel Unscrew the screw washer rubber bushing roller shown in figure A C on both sides of the cover It is now possible to assemble the new kit Prepare the screw washer rubber bushing roller align...

Page 45: ...lity PARTS INTERVAL 15 DAYS 30 DAYS 60 DAYS Brazier Trolley Lower compartment SEE PARAGRAPH CLEANINGTHETROLLEY Cleaning performed by the qualifiedTechnician PARTS INTERVAL 7 DAYS 15 DAYS 60 DAYS 1 YEA...

Page 46: ...t temperature safety probe has been triggered Let the product cool down restore the thermostat until the lockout is off and switch the product back on If the problem persists contactTechnical Assistan...

Page 47: ...leaning of the combustion chamber and thesmokeduct Checktheconditionofthe door gaskets Damp or unsuitable pellets Change the type of pellets Faulty smoke evacuation motor Check the motor and replace i...

Page 48: ...circulator by removing the plug and turning the shaft with a screwdriver Circulator does not go round Check the electrical connections of the circulator replace if necessary Radiators have air in the...

Page 49: ...8 WATER PROBE 9 SMOKETEMPERATURE PROBE 10 PELLET LEVEL SENSOR OPTIONAL 11 AIR FAN PROBE 12 SOFTWARE UPDATE 13 EXPANSION 14 SERIAL COMMUNICATION 15 PWM PUMP CONTROL 16 CONTROL PANEL 17 WATERTEMPERATURE...

Page 50: ......

Page 51: ......

Page 52: ...REV 0 8902004000 Via La Croce n 8 33074Vigonovo di Fontanafredda PN ITALY Telephone 0434 599599 a s Fax 0434 599598 Internet www red fire it e mail info red fire it 27 02 2020...

Reviews: