15-INFORMATION MENU
Technical Dept. - All rights reserved - Reproduction prohibited
BOILER STATE-INFORMATION
This menu is particularly useful if you want to verify the boiler’s working condition (State).
From the OFF screen, press the “E” Menu button, scroll with the “D” arrow key, up to the Information item, press the ok “E” key, scroll again
with the “D” arrow key up to boiler state, press OK with the “E” key and one enters the boiler State-information menu.
The items available within BOILER-STATE INFORMATION can be viewed using the “C” and “D” arrow keys and are:
state
water temp.
set
aux sensor
set
set
fumes fan
set
feed screw
set
fumes temp.
req
relay aux
spark plug
modbus com
add.
• The main boiler states that can be read on the display are:
STATE 1-9 various ignition phases
STATE 20-40 work state (power supply)
STATE 60-79 alarm state
STATE 80-84 shut off/cooling/autoeco state
STATE 85-93 auxiliary functions
STATE 94-95 cleaning state
• WATER TEMP.: Water temperature detected by the probe inside the boiler and related SET
• AUX: PROBE: detects the value measured by the aux sensor (external/storage cylinder/puffer)
• .: Value read by the Active Plus system and related SET
• FAN FUMES: Number of fumes fan revolutions and related SET
• FEED SCREW: number of feed screw revolutions and related SET
• FUMES TEMP.: temperature value read by the probe inside the boiler
• REQ: (Heating/Domestic) signals if system requires heat
• AIR FAN: Room fan operation level
• PUMP: signals if the boiler’s internal pump is turned on (ON) or turned off (OFF)
• AUX: RELAY: signals activation (ON) or the OFF state of Auxa relay
• SPARK PLUG: Signals if spark plug is turned on or off
• MODBUS COM. External interface communication state
• ADD.: Address for communicating with modbus
EXIT
INFORMATION-STOVE STATE
STATE = 0-OFF
WATER TEMP = -43°C SET = 70°C
= 471 SET = 400
SMOKE TEMP = 0 SET = 0
D
C
EXIT
INFORMATION-STOVE STATE
FEED SCREW = 0 SET = 0
SMOKE FAN = 30°C REQ = BOLL
AIR FAN = 0% POMP. = OFF
3 WAY VALVE = NO HY. IGNIT. =OFF
C
D
EXIT
INFORMATION-STOVE STATE
MODBUS COM. = OFF IND.=4