![Red-D-Arc RDA150T3 Service Manual Download Page 7](http://html1.mh-extra.com/html/red-d-arc/rda150t3/rda150t3_service-manual_1428575007.webp)
3.
Specifications
Model
Unit
RDA150T3
A
lt
er
n
at
or
Generating Type
-
Rotating Filed, Brushless 3-Phase
Synchronous Alternator
Rated Output
kVA
150
kW
120
Voltage – Three phase
V
208 / 480
Voltage – Single phase
V
120 / 240 / 277
Amps
Three phase – 480V
A
180
Three phase – 208V
A
416
Single phase – 240V
A
361 (zigzag)
Single phase – 120V
A
361 x 2 (zigzag)
Rated Frequency
Hz
60
Winding
-
3-phase, 4-wire
Star with neutral / Zig-zig
Power factor
%
80
Insulation class
-
F
Excitation
-
Self-Excitation(Brushless)
No. of poles
-
4
E
ng
in
e
Types
-
Vertical Water-cooled 4-cycle Diesel Engine
Model (Manufacturer)
-
6HK1 (ISUZU)
No. of Cylinders (bore x stroke)
(
in.
/ mm)
6 (
4.53x4.92
/ 115x125 )
Continuous rated output
kW
142
HP
190
Rated speed
rpm
1800
Displacement
cu.in.
/ liters
475.4
/ 7.790
Combustion system
-
Direct Fuel Injection with Turbo Charger
Cooling method
-
Radiator
Lubricating method
-
Forced lubrication
Starting method
-
Electric start
Fuel
-
Diesel
Lubricant oil
-
CD class
Fuel tank capacity
gal.
/ liters
74
/ 280
Lubricant volume (Full)
gal.
/ liters
10
/ 38
Cooling water volume
gal.
/ liters
6.3
/ 23.8
Starting motor capacity
V-kW
24 – 5.0
Charging dynamo capacity
V-A
24 - 50
Battery
-
105E41R x 2
Battery capacity
V-AH
12(V) – 100AH
U
n
it
Length
in.
/ mm
135.8
/ 3450
Width
in.
/ mm
48.8
/ 1240
Height
in.
/ mm
72.8
/ 1850
Dry Weight
lbs.
/ kg
6504
/ 2950
Installed Weight
lbs.
/ kg
7187
/ 3260
**Specifications subject to change without notice.
4
Summary of Contents for RDA150T3
Page 8: ...4 General 4 1 Appearance 4 2 Dimension Unit in the drawings below is shows by mm 5...
Page 9: ...6...
Page 10: ...5 General Parts Description 5 1 Equipment 7...
Page 11: ...8...
Page 12: ...9...
Page 25: ...10 Wiring Diagram 22...
Page 26: ...23...
Page 27: ...Call us toll free at 1 866 733 3272 US and Canada reddarc com...